JANDY Levolor K-2000 handleiding
Handleiding
Je bekijkt pagina 15 van 20

4.4 Pump Off Delay Variable Timer
When the water is no longer touching the High Water
Sensor, there is a delay before the controller deactivates
the High Water Pump.
The pre-set factory delay time is 20 seconds. See
Table 2, LED Indicators, and Figure 14.
To change the delay time, follow the steps in Section
4.5, Change Jumpers and Dip Switches, refer to Figure
14, and do the following:
1. Slide dip switch S1, which is set for 20 seconds, to
the OFF position.
2. Slide one of the other nine (9) dip switches to the
ON position, depending on the desired length of
the delay.
NOTE Important!Therecanonlybeone(1)dipswitch
onatanytime.
OFF ON 20 sec*
OFF ON 2.5 min
OFF ON 5 min
OFF ON 10 min
OFF ON 15 min
OFF ON 20 min
OFF ON 25 min
OFF ON 30 min
OFF ON 35 min
OFF ON 40 min
S1
S2
S3
S4
S5
S6
S7
S8
S9
S10
*Default is 20 seconds.
NOTE Only one (1) switch can be on at a time.
Figure 14. Pump OFF Delay Dip Switches
4.5 Change Jumpers and Dip Switches
WARNING
Turnoffthepowertothecontrolboxbeforestarting
thisprocedure.Failuretocomplymaycauseashock
hazard,resultinginseverepersonalinjuryordeath.
To change the jumpers and dip switches, do the
following:
1. Shut power off to the control box.
2. Remove the three (3) screws from the upper
cover plate on the front of the control box.
3. Lift and remove the cover plate from the
control box.
4. Locate the jumpers and dip switches. See
Figures 13 and 14.
5. Make adjustments to the jumper(s) and/or dip
switches, as necessary. See Sections 4.2, Fill
Safety Lockout Mode, 4.3, Pump On Delay
Variable Timer, and 4.4, Pump Off Delay Variable
Timer.
6. Replace the top cover plate, being careful to align
the LED lights with the plastic lenses in the plate.
7. Install the three (3) screws. Do not overtighten or
you will damage the plastic mounts.
8. Turn on the power to the control box. The new
timing changes will take effect.
NOTE Ifyouadjustthejumpersordipswitcheswithout
turningthepoweroffinadvance,youwillneed
tocyclethepowerfromOFFtoONaftermaking
theadjustmentsforthenewtimingchangesto
takeeffect.
The dip switches are located below the top left
controller light on the circuit board. See Figure 13.
Page 15
ENGLISH
Jandy Pro Series Levolor
®
II Electronic Water Leveler
Models K-2000
|
Installation and Operation Manual
Bekijk gratis de handleiding van JANDY Levolor K-2000, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | JANDY |
Model | Levolor K-2000 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 2855 MB |