AOP System | Installation & Operation Manual ENGLISH
Section 5. Maintenance & Service
5.1 System Electromechanical Overview
CAUTION
Disconnect power before performing service. Refer to the Important
Safety Instructions displayed in the front of this manual.
5.1.1 Ozone Modules
Each ozone module has a green light to indicate that
the ozone power supply is operating properly.
5.1.2 Ultraviolet Lamps
There are two lamps in the UV reactor of the
JAOPX500. A slight glow can be seen near the top of
the lamps during normal operation.
5.1.3 Injector Manifold
Water flowing through the injector manifold generates
the vacuum that draws ozone into the water. The
spring loaded valve automatically adjusts for various
water flow rates to keep the
Jandy AOP system
operating over a wide range of conditions.
5.1.4 Injector Tube Adapter
This connects the ozone gas line to the injector
manifold. Whenservicing this component, do not
tighten past 10 in-lbs or thecomponent may be
damaged.
5.1.5 Ozone Gas Line
Gas from the ozone modules is drawn through the
ozone gas line by the Injector and into the water.
Theozone check valve in this line prevents water
from migrating back to the ozone modules when the
Jandy AOP system is not running.
5.1.6 Ozone Module Filters
The air entering the ozone modules passes through
individual filters on each module inlet. The filters are
held in place by the rubber filter cap. (Refer to Figure
4 for a more detailed view.)
NOTE: Ballast located on enclosure ceiling not shown.
5.2 System Maintenance
Use a Phillips head screwdriver to remove the
UVaccess panel or a flat tool to open the enclosure
cover as needed.
NOTE: The Jandy AOP system will not operate until the
UVaccess panel is replaced.
5.2.1 Ozone Module Maintenance
The green ozone module lights on the ozone
modules indicate that the ozone power supply is
operating properly. When an indicator light goes out,
replace the corresponding ozone module.
5.2.2 Ozone Module Replacement Interval
Ozone module life expectancy is about 12,000
hours. Even if the ozone module light(s) are glowing,
the ozone module may be producing little or no
ozone after this period of time due to contamination
within the corona discharge ozone chamber.
5.2.3 Ozone Gas Line Replacement Interval
Replace the ozone gas line every year or sooner, if
needed. If there is evidence of water leaking past
the ozone check valve toward the ozone modules,
shut down the Jandy AOP system immediately and
replace the ozone gas line. If water entered the
ozone modules, run the filtration system so air will be
drawn through the Pzone modules and they can dry
out. Ozone modules will return to normal operation
when dry.
WARNING
Trace amounts of nitric acid may be present in the ozone gas line. Wear
proper safety equipment (gloves and eye protection) and avoid direct
contact with any condensation in the line.