Pro Series Ozone Generator
•
1
Pool Cleaner: Always plumb the cleaner T-fitting before
the ozone generator to prevent gas from affecting the cleaner
operation.
•
2
Salt Chlorinator: A salt chlorinator should be installed before
the ozone generator.
•
3
Chlorine Tab/Mineral Erosion Feeder: Always plumb
the manifold injector after any erosion feeder to avoid gas
accumulating in the feeder.
•
4
In-Floor Cleaning System: The injector manifold must be
plumbed on a different pool return leg than any in-floor cleaning
system to avoid excess back pressure on the injector. This will
also prevent gas intrusion and high oxidizer levels in zone valve
and cleaner heads.
•
5
Water Features: Avoid plumbing the injector manifold into
any leg with excessive back pressure such as those going to
fountains or restrictive wall fittings, etc.