(379IO) MODEL LS5220/5230 SALTWATER SYSTEM ENGLISH SIZE: 7.5” X 10.3” PANTONE 295U 09/30/2024
SAVE THESE INSTRUCTIONS
Page 19
379
A
English
TROUBLESHOOTING GUIDE
LED PANEL
CODE
PROBLEM SOLUTION
LED Panel Code Flash & Alarm On (
NOTE
: Always turn off the power before cleaning and servicing).
1
.
Dirt or scale on the chlorine electrode.
If the LED displays "E01" due to chlorine electrode scaling within one week,
please set the self-clean cycle time to 02H. See “Electrode Self-Clean cycle”
operation section.
Remove the chlorine electrode for inspection. Clean it if necessary. See
“Maintenance”.
2
.
Chlorine electrode cord is loose.
Ensurethatthechlorineelectrodecordispluggedrmlyintothechlorine
electrode receptacle.
3
.
Low input voltage.
Do not use extension cords, connect the product to a dedicated electrical
outlet.
4
.
Possible chlorine electrode failure.
Contact Intex Service Center. Replace the chlorine electrode if needed.
1
.
Chlorine electrode failure.
Contact Intex Service Center. Replace the chlorine electrode if needed.
1
.
Water temperature < 10ºC (50°F).
Heat the water until the water temperature reaches 10ºC (50°F) or above
with a heat pump.
It’s recommended to run the product during the daytime when the water
temperature is above 10ºC (50°F).
2
.
2-in-1 sensor failure.
Contact Intex Service Center. Replace the 2-in-1 sensor if needed.
1
.
Water temperature > 40ºC (104°F).
It’s recommended to run the product during the nighttime when the water
temperature is below 40ºC (104°F).
2
.
2-in-1 sensor failure.
Contact Intex Service Center. Replace the 2-in-1 sensor if needed.
1
. Filter pump not attached to system
and/or switch on.
Ensure the filter pump is attached and operating. See “Setup Instruction”.
2
. Circulation line is blocked.
If your unit has plunger valves, ensure that they are open.
Clear your filter cartridge and cell from debris and dirt. See “Maintenance”.
Release all trapped air in the circulation line. See the filter pump manual.
3
. Incorrect inlet and outlet hose
direction.
Check the direction of the inlet and the outlet hose. Reverse the hoses if
necessary. See “Setup Instructions”.
4
.Scaleontheowsensor.
Clean the flow sensor, paying special attention to the hinge. See
“Maintenance”.
5
. Flow sensor cord is loose.
Plug the flow sensor firmly into the flow sensor receptacle.
6
.Innertimerconictbetweenlter
pump and saltwater system.
Reset both timers on the filter pump and saltwater system. See “Operation
Instructions” section.
7
. Flow sensor failure.
Contact Intex Service Center for replacement.
1
. Low salt level / No salt.
Add salt. See “Salt & Pool Water Volumes”.
2
. 2-in-1 sensor cord is loose.
Ensure that the 2-in-1 sensor cord is plugged in firmly, screw on the 2-in-1
sensor nut securely.
3
. Scale on the 2-in-1 sensor.
Clean the sensor. See “Maintenance” section.
1
. High salt level.
Partially drain the pool and refill it with fresh water. See “Salt & Pool Water
Volumes”.
1
. Internal PCB failure.
Contact Intex Service Center. Replace the control station if needed.
1
. Salt sensor faulty, malfunction.
Replace the 2-in-1 sensor (salt / temperature).
1
. No water circulation during the salt
level detection.
2
. 2-in-1 sensor open-circuit or
short-circuit during the salt level
detection.
3
. Internal PCB failure.
Switch the filter pump on to start the water circulation, during the salt level
detection.
Ensure the 2-in-1 sensor connection is normal.
Replace the 2-in-1 sensor.
Contact Intex Service Center.