42 I-Wave PE953 Installation Guide
Copyright © 2011 Intermatic, Inc.
Section 7:
Troubleshooting
After you have completed installation and programming, make sure the
system is working OK by completing the procedures listed below. Later on,
if problems develop in using the system, going over these same procedures
will help you troubleshoot the problem.
This section will help you troubleshoot the following problems:
• Thesystemappearstowork,theLED’sturnONandOFFbutthepower
circuits and attached equipment will not turn ON.
• The 2-speed pump will not operate in 2-Speed mode.
• High speed and low speed circuits turn ON together when the pump is
turned ON.
• The circuit breaker for the pump trips every time that the Pump turns ON.
• The heater will not turn ON.
• The heater turns OFF but gets very hot after the pump turns OFF.
• Water or moisture is visible inside the screen of the Hand-Held
Controller.
• The Hand-Held Controller appears to be “LOCKED UP”.
• The PE653 Device appears to be ‘LOCKED UP”.
Problem What to do Reference/Procedure
The system appears
to work, the
LED’sturnON
and OFF but the
power circuits and
attached equipment
will not turn ON
Verify that the voltage
is correct at the PE653
power terminals.
1. Check the voltage at terminals #1 and #2 on
the PE653 using a meter.
2. Verify that the Voltage Selector is in the
correct position: either 120 V or 240 V
depending upon the voltage observed at
terminals #1 and #2.
CAUTION: If a 2-speed pump or other 240
VAC equipment is being used in the system,
the voltage must be 240 VAC.
NOTE: The PE653 will appear to function
correctly, LED’s will turn ON and it will
communicate with the PE953 Hand Held
Controller but the power relays will turn
on when 120 VAC is supplied to a 240 VAC
system.
Problem What to do Reference/Procedure
The 2-speed pump
will not operate in
2-Speed mode
Verify that all wiring
connections are
correct and that all
terminals and splices
are secure.
1. RefertotheWiringInstructionsinSection3
oftheInstallationandUsersGuide.
2. Find the Wiring Diagram that is the most like
the installation starting on page 16 of the
InstallationandUsersGuide.
3. Verify that the system is wired according to
the diagram.
Verify that the correct
voltage is present at
terminals 1 and 2.
1. Use a meter and verify voltage output from
the breaker (should be 240 VAC).
2. Use a meter to verify that the voltage at
terminals 1 and 2 is 240 VAC.
3. Turn ON circuit #1 on the PE653 using either
the Hand-Held controller or the Circuit ON/
OFF switch on the PE653.
4. Use a meter and verify voltage at pump
terminals.
NOTE: L2 must return to the second pole on
the breaker for 240 VAC to be present.
5. Verify that terminal 3 on the PE653 is
connectedtothe‘HIGH’speedterminalat
the pump.
6. Verify that terminal 4 on the PE653 is
connectedtothe‘LOW’speedterminalat
the pump.
7. Verifythatthe‘COMMON’terminalatthe
pump is connected to L2 at the breaker
panel.
Verify that your
systemiscongured
for a 2-speed pump.
8. Refer to “Conguring for a 1-Speed or
2-Speed Pump” starting on page 12.
Contact your pump service company for assistance with the pump.
Problem What to do Reference/Procedure
High speed and low
speed circuits 1 &
2) turn ON together
when the pump is
turned ON.
Conrmthatthe
system is programmed
for a 2-speed pump.
1. Press any release any button on the PE953
Hand-held Controller to wake it up.
2. VerifythatthePPE953displays“HISPD1”
or “LO SPD 2” in the upper left hand corner
of the screen.
3. Refer to the illustration on page 9.
Reprogram for
2-speed pump
operation.
Refer to “Conguring for a 1-Speed or 2-Speed
Pump” starting on page 12.