Six: Checking Out and Verifying the System 41
Providing a brighter solution.™
What to do If it doesn’t work Reference/Procedure
Verify that the Heater
is responding to
commands from the
PE953 Hand-Held
Controller.
Test the heater
response.
1. Ifnecessary,pressandreleaseanybutton
on the Hand-Held controller to wake it
from sleep.
2. Make sure that the PE953 screen displays
“POOL” or “SPA” in the lower right hand
corner. Make sure that a temperature is
displayed next to the words “POOL” or
“SPA”. Refer to the illustration on page 41.
3. Set either the POOL or SPA temperature
tovedegrees(5º)higherthanthecurrent
reading. Refer to Setting Pool and Spa
Temperatures starting on page 54 of this
manual.
4. Turn the pump ON.
Verify that the
thermostat in
the heater is set
for “high” or
“maximum.
Refertothemanufacturer’sinstallation
instructions.
Verify that all wiring
connections are
correct and that all
terminals and splices
are secure.
1. Refer to the appropriate wiring diagram with
heater connection information starting on
page16oftheInstallationandUsersGuide.
2. Refer to Fireman’s Switch Connections
starting on page 37 in Section 3 of the
InstallationandUsersGuide.
3. Find the Wiring Diagram that is the most like
your installation.
4. Verify that the system is wired according to
the diagram.
5. Refertothemanufacturer’sinstallation
instructions if your heater is not shown in
this manual.