40 I-Wave PE953 Installation Guide
Copyright © 2011 Intermatic, Inc.
What to do If it doesn’t work Reference/Procedure
Verify that the
PE953 Hand-Held
Controller will
communicate with
the PE653 Device
from everywhere on
your property.
Review the Section
covering “Testing
Z-Wave Reception”
starting on page 50.
1. Carry the PE953 Hand-Held Controller
to several parts of the area from which
commands might be sent to the PE653
Device.
2. Test the reception by turning connected
equipment ON and OFF.
3. Note if the PE653 Device fails to respond
immediately to any of the commands sent.
4. Ifcommandsaremissed,followthe
instructions for “Moving the Antenna to a
Better Location’ starting on page 18.
What to do If it doesn’t work Reference/Procedure
Verify that the
(POOL/SPA
switch on the
PE953 Hand-Held
Controller activates
the Motorized
Valve Actuators (if
installed)
Verify that the PE953
Hand-Held Controller
isconguredfor
BOTH (Pool and Spa)
1. Ifnecessary,pressandreleaseanybutton
on the Hand-Held controller to wake it
from sleep.
2. Look for the word POOL at the lower right
part of the PE953 screen (refer to illustration
on page 9).
3. IfeitherPOOLorSPAisobserved,pressand
release the P/S button on the PE953.
4. Verify that the word POOL switches to SPA
and back to POOL each time that the P/S
button is pressed.
5. VerifythatthewaterowstothePoolwhen
POOL is shown in the screen.
6. VerifythatthewaterowstotheSPAwhen
SPA is shown in the screen.
Correct the Motorized
Valve Actuator
Synchronization if the
waterowisincorrect.
Refer to Section 3: Motorized Valve Actuator
Connection and Synchronization starting on
page36oftheInstallationandUserGuide.
What to do If it doesn’t work Reference/Procedure
Verify that the Heater
is responding to
commands from the
PE953 Hand-Held
Controller.
Test the heater
response.
1. Ifnecessary,pressandreleaseanybutton
on the Hand-Held controller to wake it
from sleep.
2. Make sure that the PE953 screen displays
“POOL” or “SPA” in the lower right hand
corner. Make sure that a temperature is
displayed next to the words “POOL” or
“SPA”. Refer to the illustration on page 41.
3. Set either the POOL or SPA temperature
tovedegrees(5º)higherthanthecurrent
reading. Refer to Setting Pool and Spa
Temperatures starting on page 54 of this
manual.
4. Turn the pump ON.
Verify that the
thermostat in
the heater is set
for “high” or
“maximum.
Refertothemanufacturer’sinstallation
instructions.
Verify that all wiring
connections are
correct and that all
terminals and splices
are secure.
1. Refer to the appropriate wiring diagram with
heater connection information starting on
page16oftheInstallationandUsersGuide.
2. Refer to Fireman’s Switch Connections
starting on page 37 in Section 3 of the
InstallationandUsersGuide.
3. Find the Wiring Diagram that is the most like
your installation.
4. Verify that the system is wired according to
the diagram.
5. Refertothemanufacturer’sinstallation
instructions if your heater is not shown in
this manual.