Note to see if there is any excess noise or vibration from the
outdoor unit due to debris build-up on the fan blades etc.
Isolate the outdoor unit from the power supply by turning the 3
pole isolator switch to o (A).
Remove any dirt, leaves and debris from around the unit.
Check for any damage to the outdoor unit, repair or replace any
damaged components.
Check for any damage to the refrigerant pipework insulation,
replace any damaged areas and ensure it is sealed from the
elements.
Remove the front grill (B) so that the fan and evaporator can be
accessed easily. Clean the fan by hand with a damp so
microfibre type cloth (Do not use any solvent type cleaners).
Check the rotation and balance of the fan. If either of these is
noticeably poor, the fan blade or motor must be replaced.
Clean the aluminium fins of the evaporator by carefully spraying
water onto the back of them. Check the fins for damage as well
and repair them if necessary by using a fin alignment comb.
Check for signs of rust or scratching on the coating of the
outdoor unit, and repair faulty components or apply rust-
resistant paint if required.
Refit the front grill (B) to the outdoor unit and to prevent
vibration or noise, ensure it is located correctly and secured with
all 6 screws.
Clean the outside of the unit with a damp cloth. Do not use
aggressive or abrasive cleaning agents or solvents.
Turn the isolator switch (A) back to on.
13.3 Outdoor unit maintenance work
For environmental and technical reasons, regular cleaning and
maintenance of the outdoor unit is recommended to ensure
maximum eiciency and correct operation of the outdoor unit.
CAUTION
If the outdoor unit is not cleaned regularly,
this may lead to poor output, freezing, leaks
or problems with the compressor.
The evaporator fins are very delicate and
have sharp edges. Use safety gloves as a
precaution to prevent any injuries.
WARNING
If the outdoor unit is disconnected from
power, the electrical circuitry in the outdoor
unit will still be live for another 8 to 10
seconds.
OFF
N
L
3
A
B
Supply from indoor unit (X1)
Example of 3 pole
isolator switch