To maintain optimal battery capacity and service life:
Avoid storing a fully charged or discharged battery for long
periods. Partial charging of the battery is necessary if the battery
will be stored for an extended period.
Do not charge an extremely cold battery without bringing it into
a warm environment. Let the battery warm up for 45 minutes
before charging.
Charge the battery at a temperature range from 32 °F to 113 °F;
otherwise, the service life of the battery may be reduced.
The recommended operating temperature range is -4 °F to 122 °F.
Avoid using the battery above the maximum or below the
minimum recommended temperature range as this may
decrease the battery capacity or service life.
12. EXTERNAL POWER SUPPLY
The RICOHYBRID supports the use of a 5V external power supply,
such as a mobile power bank. To connect to an external power
supply:
1. Open the USB-C cover (11).
2. Connect the USB-C end of the data cable (19) to the USB-C
port(11) on the side of the RICOHYBRID.
3. Connect the other end of the data cable to the external power
supply.
4. The RICOHYBRID will switch to operation from the external
power supply, and the internal battery pack will begin slowly
charging.
5. In the status bar, the battery status icon will alternate with
the battery charging icon.
6. If the external power supply is disconnected, the RICOHYBRID
will automatically switch to the battery pack, if installed, without
powering o.
NOTE: Do not connect the RICOHYBRID to an external device
with a power supply that exceeds the 3.0 USB cable.
4. Firmly press the battery in to fully insert it.
5. Rotate the pull-ring counterclockwise 90 degrees to the vertical
position to lock the battery pack in place.
6. Flip the pull-ring down so that it is flush with the battery pack.
WARNING: The RICOHYBRID can only be powered by a factory-
supplied IBP-1H battery pack. Using any other battery pack may
cause irreparable damage to the rifle scope or cause a fire. Any
damage from using an improper battery pack will not be covered
by warranty.
10. REMOVING THE BATTERY PACK
To remove the battery pack from the RICOHYBRID:
1. Lift the pull-ring (16) on the battery pack (15) and rotate it
clockwise 90 degrees until it is horizontal to the battery pack.
2. Pull the battery pack out.
11. BATTERY SAFETY WARNINGS
WARNING: Only use the battery charger supplied with the battery
pack. The use of any other charger may irreparably damage the
battery pack or the charger and may cause a fire. Any damage from
using an improper battery charger will not be covered by warranty.
WARNINGS:
Do not use a battery charger, power adapter, or USB cable that
has been modified or damaged.
Do not expose the battery to high temperatures or flames, and
do not immerse in water.
Do not leave the battery unattended while charging.
Do not leave the battery in the charger for long periods after full
charge is reached. Charging time should not exceed 24 hours.
Keep the battery pack out of the reach of children and pets.
The battery is equipped with short-circuit protection. However,
any situation that may cause short-circuiting should be avoided.
Do not disassemble, modify, hit, or drop the battery pack.
Do not connect the battery to any external device with an
electrical current that exceeds permitted levels.
Do not connect an external device with a current supply that
exceeds a 3.0 USB port.