InfiRay Rico Hybrid HYH75W handleiding
Handleiding
Je bekijkt pagina 22 van 31

40 41
ZEROING PROFILE MENU > BALLISTICS SOLVER
SUBMENU
Turn on the ballistics
solver
1. In the zeroing profile
submenu, rotate the
Rotary Encoder to
select the ballistics
solver
menu item.
2. Short press the
Rotary Encoder to
enter the submenu.
3. Rotate the Rotary
Encoder to toggle
the ballistics solver
on / o. The ballistics
solver is o by
default.
4. When the ballistic
solver is on, a
secondary aiming
point will be
superimposed on the
BDC reticle based
on your customized
shooting table and the target distance provided by the optional
LRF module or manually input in the quick menu.
5. Long press the Rotary Encoder to confirm the selection and
return to the home screen.
Zeroing
Select or customize a
zero distance
In the zeroing menu,
you can select a preset
zero distance, customize
a preset zero distance,
and adjust the reticle
position for the selected
zero distance. The
RICOHYBRID supports
custom zero distances of
1 to 999 yards or 1to 999 meters.
NOTE: Before selecting or customizing a zero distance, please
select a gun type (A, B, or C) and a bullet type (1, 2, or 3). See the
Zeroing Profile section on page38.
1. Long press the Rotary Encoder to enter the main menu.
2. Rotate the Rotary Encoder to select the zeroing menu item.
3. Short press the Rotary Encoder to enter the submenu. Three
zero distances are shown in the submenu.
ZEROING MENU > ZERO DISTANCE SUBMENU
Select or customize a preset zero distance
1. In the zero distance submenu, rotate the Rotary Encoder to
select a zero distance option.
2. Short press the Rotary Encoder to enter the submenu for the
selected zero distance.
3. In the submenu for the selected zero distance, you may:
a. Enter the reticle zeroing interface to adjust the
X/Yposition of the reticle at the selected zero distance. See
Reticle Zeroing on the next page.
b. Customize the selected preset zero distance as needed.
See Zeroing Menu > Customize Zero Distance on
page43.
ZEROING MENU > ZERO DISTANCE SUBMENU >
RETICLE ZEROING
Adjust the reticle
position of the selected
zero distance.
In the reticle zeroing
interface, the X/Y position
of the reticle may be
adjusted to match the
point of impact.
1. In the submenu for
the selected zero
distance, the reticle
zeroing
menu
item is selected by
default. Short press
the Rotary Encoder
to select it and enter
the reticle zeroing
interface.
2. The reticle zeroing
interface has the
following features:
1 X: Horizontal
point of impact
change (in cm or inches).
2 Y: Vertical point of impact change (in cm or inches).
Bekijk gratis de handleiding van InfiRay Rico Hybrid HYH75W, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | InfiRay |
| Model | Rico Hybrid HYH75W |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 8175 MB |



