Zeroing Profile
Adjust the zeroing and ballistic settings
In the zeroing profile menu, you can set the gun type and bullet
type, edit the shooting table, and turn on or o the BDC reticle and
ballistics solver.
1. Long press the Rotary Encoder to enter the main menu.
2. Rotate the Rotary Encoder to select the zeroing profile menu
item.
3. Short press the Rotary Encoder to enter the submenu.
ZEROING PROFILE MENU > GUN TYPE SUBMENU
Shooting Prof
Zeroing
Set the gun type
1. In the zeroing profile
submenu, rotate the
Rotary Encoder to
select the gun type
Shooting Prof
Zeroing
menu item.
2. Short press the
Rotary Encoder to
enter the submenu.
3. Rotate the Rotary
Encoder to move
through the options,
A, B, andC. The selection changes in real-time, and the gun
Shooting Prof
Zeroing
icon and selected type, A, B, or C, appear in the status bar.
4. Long press the Rotary Encoder to confirm the selection and
return to the home screen.
ZEROING PROFILE MENU > BULLET TYPE SUBMENU
Set the bullet type
1. In the zeroing profile
submenu, rotate the
Rotary Encoder to
select the bullet type
menu item.
2. Short press the
Rotary Encoder to
enter the submenu.
3. Rotate the Rotary
Encoder to move
through the options,
1, 2, and3. The selection changes in real-time. The bullet icon
and type, 1, 2, or 3, appear in the status bar.
4. Long press the Rotary Encoder to confirm the selection and
return to the home screen.
ZEROING PROFILE MENU > SHOOTING TABLE
SUBMENU
Edit the shooting table
1. In the zeroing profile
submenu, rotate the
Rotary Encoder to
select the shooting
table
menu item.
2. Short press the
Rotary Encoder to
open the shooting
table.
3. The oset corresponding to the zeroing distance must be
entered in the shooting table. For example, if the zeroing
distance is 50yd, data must be entered in the table cell below
50yd in the shooting table.
4. In the shooting table:
a. Input osets corresponding to two or more distances to
build a ballistic solution.
b. “-” indicates a value located below the zeroing point, and
“+” indicates a value located above the zeroing point.
c. When “--.--” displays, no data has been input in the table cell.
d. The accepted range for data values is 00.00 to 99.99.
5. Long press the Rotary Encoder to close the table and return to
the home screen.
ZEROING PROFILE MENU > BDC RETICLE SUBMENU
Turn the BDC reticle
on / o
1. In the zeroing profile
submenu, rotate the
Rotary Encoder to
select the BDC reticle
menu item.
2. Short press the
Rotary Encoder to
enter the submenu.
3. Rotate the Rotary
Encoder to toggle
the BDC reticle on / o. The BDC reticle is o by default.
4. When turned on, the BDC reticle is active and overrides the
reticle set in the quick menu. If you have already zeroed at the
selected distance, the BDC reticle will reference that location as
its zero position.
5. Long press the Rotary Encoder to confirm the selection and
return to the home screen.