InfiRay BOLT TH50C V2 handleiding
Handleiding
Je bekijkt pagina 26 van 28

48 49
30. GENERAL TROUBLESHOOTING
The troubleshooting table below lists issues that may occur when
operating the BOLT TH50CV2. Carry out the recommended
troubleshooting steps in the order shown in the table. Please contact
iRayUSA at 800-769-7125 or irayusa.com/support or an authorized
vendor for assistance before attempting to perform any modifications
or repairs beyond the scope of the troubleshooting procedures in
this manual. Unauthorized repairs or modifications will void your
warranty.
ISSUE POSSIBLE CAUSES TROUBLESHOOTING STEPS
The TH50CV2 will not turn on.
The built-in battery pack is very low or
has completely discharged.
Charge the built-in battery pack.
The TH50CV2 can not connect to a
computer or external power supply.
External power supply has completely
discharged.
Check the external power supply and charge it if necessary.
Computer is turned o. Power on the computer.
Data cable is damaged. Replace the USB-C to analog RCA/USB data cable.
The TH50CV2 can not connect to
the mobile device (smartphone or
tablet).
Wi-Fi is not turned on. Turn on the Wi-Fi in the main menu. See Main Menu > Wi-Fi on page31.
Wrong Wi-Fi password entered.
On the mobile device, go to Settings > Wi-Fi and enter the correct password.
The default password is 12345678. See Main Menu > Wi-Fi on page31.
Too many Wi-Fi signals near the
TH50CV2.
Move the TH50CV2 and mobile device to an area with no or fewer Wi-Fi
signals.
Wi-Fi signal is lost or interrupted.
Smartphone or tablet is out of range
of a strong Wi-Fi signal, or there are
obstacles between the TH50CV2 and
the mobile device.
• Try again when Wi-Fi signal is stable.
• Relocate the TH50CV2 closer to the Wi-Fi signal.
The image is fuzzy, not clear,
not balanced, with artifacts.
Non-uniformity correction is required.
Perform a non-uniformity correction. See Non-uniformity Correction on
page23.
The image is too dark. Display brightness level is too low.
From the home screen, short press the Brightness button to adjust the display
brightness.
The GUI is clear, but the image
is fuzzy.
The lens is not focused.
• Adjust the focus on the target by rotating the Objective Lens Focus Ring (14)
• Adjust the image sharpness in the quick menu. See Using the Quick Menu
on page20.
There is dust on the interior or exterior
optical surfaces of the lens.
• Wipe the outside optical surfaces with the included microfiber lens cloth.
There is condensation on the interior
or exterior optical surfaces of the lens.
• Wipe the outside optical surfaces with the included microfiber lens cloth.
• Allow the TH50CV2 to dry by leaving it in a warm, dry environment for at
least 4 hours.