InfiRay BOLT TH50C V2 handleiding

28 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 20 van 28
36 37
f. When adjusting your zero at a distance of 50 yards, one
click will change the impact point by 0.22” as shown in the
X and Y coordinate displays. At 100 yards that same click
moves 0.43”. At 200 yards one click moves 0.87”.
g. Changing your zero distance will change the distance
of your X/Y adjustments automatically. If your selected
zero distance has a correction of 1.30” at 100 yards, it
will automatically change to 2.60” if you change the zero
distance to 200 yards.
6. Short press the Power
Button to clear the reticle position
and exit the reticle zeroing interface; OR
7. Long press Control Turret to save the reticle position and return
to the home screen. A 5-second countdown appears on the
screen, followed by “Saved Successfully.
8. Take a confirmation shot—the point of impact should now match
the point of aim. If not, adjust the X/Y position of the reticle
again.
ZEROING MENU > ZERO DISTANCE SUBMENU >
CUSTOMIZE ZERO DISTANCE
Customize a preset zero
distance
The BOLT TH50CV2
supports custom zero
distances of 1 to 999 yards
or 1 to 999 meters.
1. In the submenu for the
selected zero distance,
rotate the Control Turret
to select the distance
customization
menu
item.
2. Short press the Control
Turret to customize the
zero distance. The selected distance is back-highlighted in green
and white arrows appear above and below the first digit.
3. Rotate the Control Turret to increase or decrease the value of
the first digit, from 0–9.
4. Short press the Control Turret to switch between the three digits.
The two triangle icons will move to indicate the selected digit.
5. Long press the Control Turret to save the custom zero distance
and return to the zero distance submenu.
6. The new zero distance appears in the bottom status bar.
R e s e t Z e r oi ng D i s t a nc e
100y
200y
100y
300y
Calibration
Select non-uniformity
correction mode
The BOLT TH50CV2 has
three non-uniformity
correction (NUC) modes:
Automatic(A), Manual(M) and
Background (B).
1. Long press the Control
Turret to enter the main
menu.
2. Rotate the Control
Turret to move through
the menu to select the
calibration
menu item.
3. Short press the Control
Turret to enter the
calibration submenu.
4. Rotate the Control
Turret to move through
the submenu options,
Automatic(A), Manual(M),
and Background (B).
Automatic(A) is selected
by default.
5. The selected NUC mode,
A, M, or B, appears in the top status bar.
6. Long press the Control Turret to confirm the selection and return
to the home screen.
Standby
Set automatic standby status and time
To conserve battery, the
TH50CV2 may be set to
automatically enter standby
mode after a specified length
of inactivity (2, 4, or
6 minutes).
1. Long press the Control
Turret to enter the main
menu.
2. Rotate the Control
Turret to move through
the menu to select the
standby
menu item.
C a l i b r a t i on
C a l i b r a t i on
Ma n u a l
Au tom a ti c
Ba c k g r ou n d
S t a nd b y

Bekijk gratis de handleiding van InfiRay BOLT TH50C V2, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkInfiRay
ModelBOLT TH50C V2
CategorieNiet gecategoriseerd
TaalNederlands
Grootte7222 MB