InfiRay BOLT TH50C V2 handleiding
Handleiding
Je bekijkt pagina 19 van 28

34 35
NOTE: Before selecting or customizing a zero distance, you must
set a zeroing profile (A, B, or C). See Main Menu > Zeroing Profile
on the previous page.
1. Long press the Control Turret to enter the main menu.
2. Rotate the Control Turret to move through the menu to select
the reset zeroing distance
menu item.
3. Short press the Control Turret to enter the reset zeroing distance
submenu. There are three zero distances available in the
submenu.
ZEROING MENU > ZERO DISTANCE SUBMENU
Select or customize a
preset zero distance
1. In the zeroing menu,
rotate the Control Turret
to select a zero distance.
2. Short press the Control
Turret to enter the
submenu for the selected
zero distance.
3. In the submenu for the
selected zero distance,
you may:
a. Enter the reticle
zeroing interface
to adjust the X/Y position of the reticle
at the selected zero distance. See Reticle Zeroing below.
b. Customize the selected preset zero distance
. See
Customize Zero Distance on page36.
ZEROING MENU > ZERO DISTANCE SUBMENU >
RETICLE ZEROING
Adjust the reticle position
of the selected zero
distance.
In the reticle zeroing interface,
the X/Y position of the reticle
may be adjusted to match the
point of impact. Refer back to
Zeroing the BOLT TH50CV2
on page22, as needed.
1. In the submenu for the
selected zero distance,
the reticle zero
menu
item is selected by
default. Short press the
Control Turret to select and enter the reticle zeroing interface.
R e s e t Z e r oi ng D i s t a nc e
200y
100y
300y
R e s e t Z e r oi ng D i s t a nc e
100y200y
100y
300y
2. The reticle zeroing
interface has the
following features:
1 X: Horizontal point
of impact change (in
cm or inches).
2 Y: Vertical point of
impact change (in cm
or inches).
3 Freeze Icon: Appears
when the image is
frozen.
4 Reticle: Shows the
new reticle position.
5 White Dot: Indicates center of initial reticle position.
NOTE: The red “X” indicates the point of impact. It is shown in the
figure for illustration purposes and is not an interface element.
3. Center the reticle on the aiming point and long press the
Photo and Palette Buttons at the same time to freeze
the image. The image freeze
icon will appear above the X/Y
coordinates.
4. Select the axis (X or Y) along which to move the cursor:
a. Short press the Control Turret to switch between X and Y.
The selected axis is back-highlighted in green. The X-Axis is
selected by default.
5. Adjust the X/Y position of the reticle until the reticle matches the
point of impact.
a. X (horizontal) is the windage and Y (vertical) is the elevation.
b. Upon moving the
reticle, a white dot
appears onscreen,
representing the
original position of
the reticle.
c. Rotate the
Control Turret
counterclockwise to
move in the positive
direction: X=Right
and Y=Up.
d. Rotate the Control
Turret clockwise to
move in the negative direction: X=Left and Y=Down.
e. Rotate one click to move the reticle in the corresponding
direction by 1 pixel. One full rotation (20 clicks) is equivalent
to 20 pixels.
X =
0.00
i n Y=
0.00
i n
Z e r oi ng 1 0 0 y
X =
+
52.45
i n Y=
+ 6 2.41
i n