Troubleshooting
ERROR
CODE
DESCRIPTION POSSIBLE CAUSE
A1
Indoor unit room temperature sensor
failure
• Damage to the indoor unit’s room temperature sensor.
• Bad contact of the room temperature sensor in the indoor unit.
• Damage to the wiring of the indoor unit’s room temperature
sensor.
• Damage to the base plate of the indoor unit.
A2
Indoor evaporator core temperature
sensor failure
• Damage to the indoor unit’s temperature sensor.
• Bad contact of the temperature sensor in the indoor unit.
• Damage to the indoor unit temperature sensor wiring.
• Damage to the indoor unit’s base plate.
A3
Indoor unit liquid pipe temperature
sensor failure
• Damage to the indoor unit’s liquid pipe temperature sensor.
• Bad contact of the liquid pipe temperature sensor in the indoor
unit.
• Damage to the wiring of the liquid pipe temperature sensor in
the indoor unit.
• Damage to the main base plate of the indoor unit.
• Damage to the gas pipe temperature sensor of the indoor unit.
A4
Failure of indoor unit gas pipe tempe-
rature sensor failure
• Damage to the gas pipe temperature sensor of the indoor unit.
• Bad contact of the gas pipe temperature sensor in the indoor
unit.
• Damage to the wiring of the indoor unit’s gas pipe temperature
sensor.
• Damage to the base plate of the indoor unit.
A5
Failure during draining. • Switch is disconnected or wiring is damaged.
• Wrong model parameter setting
• Drain plug
• Pump damage
A6
Indoor unit fan motor failure • Low voltage
• Poor wiring
• Damage to the base plate of the indoor unit
• Damage to the motor
A8
Failure of EEPROM module of indoor
unit
• The motherboard of the indoor unit is broken.
• EEPROM module is broken.
Error codes on variable speed models
Once the indoor and outdoor units have been turned off due to a fault, the error code will be displayed
on the remote controller. In case the protection system is normal, no fault code will be displayed on the
indoor unit.
no fault code will be displayed on the indoor unit. Among other things, the remote controller does not
send warnings automatically, so it is necessary to press the CHECK button to display the corresponding
error codes.corresponding fault codes. The remote control displays the fault codes directly.
Once the faults have been cleared, the indication on the display will disappear automatically.