Troubleshooting
CÓDIGO
DE ERROR
DESCRIPCIÓN POSIBLE CAUSA
A9
Communication error between out-
door unit and indoor unit.
• Damage to the base plate of the indoor unit
• Damage to the base plate of the outdoor unit
• Poor wiring
AA
Communication error between the
remote controller and the main board
of the indoor unit.
• Poor wiring.
• Damage to the remote control
• Damage to the base plate of the indoor unit.
H1
Pressure gauge failure • System piping blockage
• Pressure gauge failure
H4
Fault in the low pressure gauge. • Lack of coolant
• Shut-off valve not opened
C1
Failure in the low pressure gauge. • Damage to the outdoor unit’s room temperature sensor.
• Bad contact of the outdoor unit’s room temperature sensor.
• Damage to the wiring of the outdoor unit’s room temperature
sensor.
• Damage to the outdoor unit’s base plate.
C2
Outdoor unit room temperature sen-
sor failure.
• Damage of defrost temperature sensor in outdoor unit
• Bad contact of the outdoor unit defrost temperature sensor.
• Damage to the wiring of the outdoor unit defrost temperature
sensor.
• Damage to the base plate of the outdoor unit.
C3
Outdoor unit defrosting temperature
sensor failure Outdoor unit defrosting
temperature sensor failure
• Damage to the discharge temperature sensor of the outdoor
unit.
• Bad contact of outdoor unit outlet temperature sensor.
• Damage to the wiring of the outdoor unit outlet temperature
sensor.
• Damage to the outdoor unit’s base plate.
C6
Failure in the output temperature
sensor.
• Damage to the outdoor unit’s inlet temperature sensor.
• Bad contact of the inlet temperature sensor in the outdoor unit.
• Damage to the wiring of the outdoor unit’s suction temperature
sensor.
• Damage to the base plate of the outdoor unit.
C8
Failure in the inlet temperature sensor. • Damage to the outdoor unit’s temperature sensor.
• Bad contact of the temperature sensor in the outdoor unit.
• Damage to the wiring of the outdoor unit temperature sensor.
• Damage to the outdoor unit’s base plate.