Pressure-resistant position sensor for hydraulic cylinders MFH2xx
© ifm electronic gmbh 11660562 / 00 06 / 2025 17
• Low active = normally closed
Select Parameter > SSC1.x.
Select SSC1.x Config. Logic and set the switch point logic for the switching signal channel SSC1.x.
10.3 Deactivating the output
The output signal for the output can be deactivated as follows:
Deactivated: The switching channel is deactivated, i.e. the switching status is permanently in the inactive
state: With High active setting permanently “low”, with Low active setting permanently “high”.
Select Parameter > SSC1.x.
Select SSC1.x Config.Mode and set Deactivated.
10.4 Configuring switch points manually
During configuration, set the mode before defining the other parameters such as switch point and hys-
teresis.
Single point mode:
Select SSC1.x Config.Mode and set the Single Point mode.
Select SSC1.x Param.SP1 and set switch point 1.
Select SSC1.x Config.Hyst and set the hysteresis.
Two-point mode:
Select SSC1.x Config.Mode and set the Two Point mode.
Select SSC1.x Param.SP1 and set switch point 1.
Select SSC1.x Param.SP2 and set switch point 2.
Window mode:
Select SSC1.x Config.Mode and set the Window mode.
Select SSC1.x Param.SP1 and set switch point 1.
Select SSC1.x Param.SP2 and set switch point 2.
Select SSC1.x Config.Hyst and set the hysteresis.
Save the changed parameter settings on the device.
All setpoints and reset points, with or without hysteresis, must be within the setting range of 5
to 195. This restriction applies to each mode, so that it is possible to switch between the
modes.
If the hysteresis is set to 0, the device adopts the Auto setting. This setting corresponds to a
hysteresis value of 10.
10.5 Switching delay
For both switching channels, a separate delay time can be set.
Parameter setting: