MFH2xx Pressure-resistant position sensor for hydraulic cylinders
16 © ifm electronic gmbh 11660562 / 00 06 / 2025
10 Parameter setting
The parameters are set via the IO-Link interface on pin 4 using the parameter setting software.
Parameters can be set before installation or during operation.
If you change parameters during operation, this will influence the function of the plant.
Ensure that there will be no malfunctions in your plant.
During parameter setting the unit remains in the operating mode. It continues to monitor with the existing
parameter until the parameter setting has been completed.
The device parameters can be set via the IO-Link interface in the following ways, for example:
Parameter setting via a suitable parameter setting software, e.g. ifm moneo|configure
Parameter setting via a PLC
Parameter setting via an IIoT application
Requirements for parameter setting via the IO-Link interface:
The Input Output Device Description (IODD) for the device in case of parameter setting via a parame-
ter setting software, see
documentation.ifm.com
The IO-Link interface description (PDF) for the device in case of parameter setting via a PLC or IIoT
application, see
documentation.ifm.com
An IO-Link master
Connect the IO-Link master to the parameter setting software, the PLC or the IIoT application.
Connect the device to a suitable free port of the IO-Link master.
Set the port of the IO-Link master to the IO-Link operating mode.
The device changes to the IO-Link mode.
Change the parameter settings in the software.
Write the parameter settings to the device.
Support for system integration and parameter setting via IO-Link:
Manual of the parameter setting software (e.g. moneo)
Explanations and startup packages at
ifm.com/cnt/io-link-system-integration
.
When the hydraulic cylinder is replaced, it may also be necessary to adapt the device settings.
10.1 Output polarity of the switching outputs
The parameter P-n can be used to select whether the switching outputs are positive switching or negative
switching.
Select Parameters > Basic settings.
Select P-n and set PnP or nPn.
10.2 Logic
The logic of the switching channels can be set.
Selectable values:
High active = normally open