u Save the project.
w The device has been integrated into the TwinCAT project.
9.2.2.1 Using Ethernet over EtherCAT (EoE)
The device supports the Ethernet over EtherCAT (EoE) protocol.
To use EoE, the following conditions must be met:
• The EtherCAT master supports the EoE protocol.
• EoE is activated and configured on the EtherCAT master and the EtherCAT slave.
The configuration differs depending on the network topology used. The following example shows the
configuration steps for a direct connection between a PC with TwinCAT and the device. The EtherCAT
master is assigned to the Ethernet interface of the PC.
Requirements:
ü The device is integrated into the project.
ü IP parameters of the Ethernet interface of the TwinCAT PC are set (e.g. IP address: 192.168.3.1,
subnet mask: 255.255.255.0)
u In the [Solution Explorer]: Select the node of the EtherCAT master.
w The detail window shows device settings.
u Select the [EtherCAT] tab.
w The detail window shows EtherCAT settings.
u Click on [Advanced Settings…].
w A dialogue window appears.
u Select the [EoE Support] menu item.
u Set the parameters as follows: