Hymer Exsis I (2025) handleiding
Handleiding
Je bekijkt pagina 127 van 240

Electrical system 8
Exsis I/T - 01/23-1 - EHG-0027-02EN 127
◼ Switch off both safety cut-outs (Fig. 106,1 and 2) in the fuse box
(Fig. 106,3).
◼ Loosen the detent on the camping distributor and unplug the connecting
cable from the socket.
◼ Loosen the detent on the vehicle unplug the plug connector and close
the cover of the 230 V connection.
8.9 Fuses
Only replace defective fuses when the cause of the defect is known
and has been remedied.
Replace defective fuses only after the power supply has been turned
off.
Never bridge or repair fuses.
Only replace faulty fuses with a new fuse with the same rating.
8.9.1 12 V fuses
The appliances connected to the 12 V power supply in the living area are
fused individually. The fuses are accessible at different positions in the vehi-
cle.
Before changing fuses, take the function, value and colour of the relevant
fuses from the following specifications. When changing fuses, only use flat
fuses with the values shown below.
Some signals are protected by "Polyswitch" fuses. Polyswitch is an internal
self-resetting fuse. After the overcurrent or short circuit has been remedied,
the operating current is enabled again automatically. This can take a few
seconds (cooling-down phase).
The fuses are installed in the vicinity of the starter battery.
1 Jumbo flat fuse 50 A/red
(for transformer/rectifier)
2 Flat fuse 20 A/yellow
(for refrigerator)
3 Flat fuse 10 A/red
(for LED front headlights/SE)
Fig. 108 Fuses (starter battery)
Unplugging the connection:
Fuses on the starter
battery