8 Electrical system
126 Exsis I/T - 01/23-1 - EHG-0027-02EN
8.8.2 Connecting the 230 V power supply
The external 230 V power supply must be protected by fuse with a
fault current protection switch (FI-switch, 30 mA).
To prevent overheating, the cable must be fully uncoiled from the ca-
ble reel.
In case of doubt or if the 230 V supply is not available or is faulty, con-
tact the operator of the power supply device.
The 230 V connection in the vehicle is equipped with a fault current pro-
tection switch (FI-switch).
For the connection points on camp sites (camping distributors) fault cur-
rent protection switches (FI-switches, 30 mA) are obligatory.
The vehicle can be connected to an external 230 V power supply. As a prin-
ciple, only use the 230 V connection on the vehicle (CEE socket outlet) for
connecting.
Fig. 106 Safety cut-out and FI-switch
(230 V fuse box)
Fig. 107 230 V connection on the ve-
hicle (CEE socket outlet)
The second safety cut-out (Fig. 106,2) is optional. Whether this safety
cut-out is present or not depends on the equipment of the vehicle.
◼ Check whether the power supply device is suitable regarding connec-
tion, voltage, frequency and current.
◼ Check whether the cables and connections are suitable.
◼ Check the plug connectors and cables for visible damage.
◼ Switch off both safety cut-outs (Fig. 106,1 and Fig. 106,2) in the fuse
box (Fig. 106,3).
◼ Open the cover of the 230 V connection on the vehicle (Fig. 107) and
insert the plug connector. Ensure that the detent of the spring-mounted
pivoting cover is engaged in position.
◼ Plug the connector of the connecting cable into the socket of the camp-
ing distributor. Ensure that the detent of the spring-mounted flap is also
engaged here.
◼ Switch on both safety cut-outs in the fuse box.
◼ When the vehicle is connected to the 230 V supply, press the test button
(Fig. 106,5) of the fault current protection switch (FI-switch) (Fig. 106,4)
in the fuse box (Fig. 106,3). The fault current protection switch must trip.
◼ Switch the fault current protection switch (Fig. 106,4) back on again.
Connecting the vehicle:
Checking the fault current
protection switch:
Bekijk gratis de handleiding van Hymer Exsis I (2025), stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Hymer |
| Model | Exsis I (2025) |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 25423 MB |