Electrical system 8
Exsis I/T - 01/23-1 - EHG-0027-02EN 125
The Alarm warning light (Fig. 105,3) starts to flash and the corresponding
tank symbol (Fig. 105,7 or 8) lights up as soon as the water tank is empty or
the waste water tank is full.
◼ Fill water tank or empty waste water tank.
If the vehicle is connected to the 230 V power supply, the 230 V indica-
tor lamp is lit even if the 12 V power supply is switched off via the rotary
knob.
The 230 V indicator lamp (Fig. 105,10) illuminates whenever line voltage is
available at the transformer/rectifier input.
8.8 230 V power supply
Only allow qualified personnel to work on the electrical system.
Have the vehicle's electrical system checked by a qualified electrician
at least once every 3 years. If the vehicle is used frequently, an an-
nual check is recommended.
The 230 V power supply provides electricity for the following devices (if pre-
sent):
⚫ sockets with earth contact for appliances with maximum 10 A
⚫ refrigerator
⚫ transformer/rectifier
⚫ an auxiliary charging unit
⚫ air conditioning unit
The electrical appliances connected to the 12 V power supply of the living
area are supplied with voltage by the living area battery.
Connect the vehicle to an external 230 V power supply system as often as
possible. The charger module in the transformer/rectifier automatically
charges the living area battery. In addition to this, the starter battery is
charged with a float charge of 2 A.
Depending on the equipment, optional devices are fuse-protected by their
own two-pole automatic circuit breaker.
8.8.1 230 V connection (CEE socket outlet)
Overvoltage can damage connected devices. Overvoltage can be
caused by lightning, irregular voltage sources (e.g. petrol-operated gen-
erators) or power connections on ferries for example.
⚫ The connecting cable, the plug connectors at the point of supply and the
plug connector to the vehicle must comply with IEC 60309. The stand-
ard designation for the plug connectors is "CEE blue".
⚫ Use H07RN-F rubber sheathed cable with a minimum cable cross-sec-
tion of 2.5 mm² and a maximum length of 25 m.
⚫ Earth contact connectors (safety) are not permitted. The interconnection
of CEE/safety adapters is also prohibited.
Tank alarm
Measures:
230 V indicator lamp
Requirements concerning
the 230 V connection