8 Electrical system
136 B-MC I/T - 01/23-1 - EHG-0016-03EN
If the battery capacity indicator does not reach 100 % any more after a
longer charging time, contact the customer service.
Transport and dispose of the lithium battery only as prescribed by the
manufacturer.
Observe the manufacturer's instruction manual.
The lithium battery consists of six modules and is connected in parallel to
the default lead battery. The lithium battery tolerates frequent charge cycles
better than the lead battery and takes up most of the charge cycles. This
extends the lifetime of the lead battery.
The lithium battery is equipped with a protective function against overload
and total discharge.
The lithium battery is installed next to the lead battery in a compartment of
the double floor and is accessible via a floor trap.
The integrated intelligent discharge management ensures that, while
discharging, the current is first drawn from the lithium battery and only then
from the lead battery. When the lithium battery is providing the current, the
lead battery serves as backup storage.
In case of large power requirement, the current is drawn in parallel from
both, the lithium battery and the lead battery.
During the charging procedure, the lead battery is charged in the first place,
and then the lithium battery.
Fully charge the battery system after recommissioning or longer periods
of inactivity.
Do not remove the fuses between the lithium battery and lead battery,
otherwise the winter storage support will not work, and the lead battery
may be damaged.
In the case of adequate use, the lithium battery has a lifetime of up to
10 years.
Prior to storage, fully charge the battery system and disconnect it from the
transformer/rectifier (switch off battery cut-off switch on the transformer/rec-
tifier).
At the latest, check the charge status on the display of the lithium battery
after 6 months. In order to do this, switch on the battery cut-off switch on the
transformer/rectifier. Charge battery if necessary.
In case of a longer storage period: charge and discharge battery several
times if necessary to obtain full performance of the battery system.
Store the battery system in a place that is dry and well ventilated.
Observe the recommended storage temperature between 10 and 20 °C.
Take any further details on the storage temperature from the manufacturer's
instruction manual.
Position
Integrated discharge
management
Charging
Storage