12 31-5000884 Rev. 6
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
1
2
The maximum refrigerant charge amount (M)
Indoor Unit Outdoor Unit M(oz)
HW09HN2DA* 1H09HN2DA*
32.8HW12HN2CA* 1H12HN2CA*
HW12HN2DA* 1H12HN2DA*
HW18HN2CA* 1H18HN2CA*
45.9
HW18HN2DA* 1H18HN2DA*
HW24HN2CA* 1H24HN2CA*
52.9
HW24HN2DA* 1H24HN2DA*
A:
Contains fluorinated greenhouse gases covered by
the Kyoto Protocol
B:
Factory refrigerant charge of the product: see unit
nameplate
C:
Additional refrigerant amount charged in the field D
total refrigerant charge
E: Outdoor unit
F:
Refrigerant cylinder and manifold for charging
GWP=global warming potential
1 – The factory refrigerant charge of the product.
2
The additional refrigerant amount charged in the
field.
1+2 – The total refrigerant charge.
Model Factory Charge (oz)
1H09HN2DA*
25.751H12HN2CA*
1H12HN2DA*
1H18HN2CA*
38.8
1H18HN2DA*
1H24HN2CA*
45.9
1H24HN2DA*
Contains fluorinated greenhouse gases
covered by the Kyoto Protocol