C. Ice Storage Bin Drain
In some conditions, slime may build up inside the ice storage bin drain and prevent
water from draining properly. To prevent this buildup, perform the following procedure
once every 3 months or as often as necessary for conditions.
NOTICE
If the ice storage bin drain becomes clogged, water could build up in the bin and
overow, leading to costly water damage.
1) Move the control switch to the "OFF" position. WARNING! To reduce the risk of
electric shock, do not touch the control switch with damp hands.
2) Remove all ice from the ice storage bin.
3) Mix a batch of sanitizing solution by diluting 0.34 . oz. (10.1 ml or 0.68 tbs) of a
7.5% sodium hypochlorite solution (chlorine bleach) with 1 gallon (3.8 l) of warm water.
Using a chlorine test strip or other method, conrm that you have a concentration of
about 200 ppm.
4) Slowly pour the sanitizing solution into the ice storage bin.
5) After all of the solution has drained, clean the ice storage bin liner with a neutral cleaner.
Rinse thoroughly with clean water.
6) Move the control switch to the "ICE" position to start the automatic icemaking process.