8
4 Connect wires to the UWP.
Refer to the notes you recorded on
the chart during removal. Depress
the tabs to put the wires into the
inner holes of their corresponding
terminals on the UWP (one wire per
terminal) until it is firmly in place.
Gently tug on the wires to verify
that they are secure.
Tip: If you need to release the wires
again, push down the terminal tabs
on the sides of the UWP.
This wiring is just
an example; yours
may vary.
Heat Pumps
Alternate wiring (for heat pumps only)
WIRING NOTES:
1. Keep R Slider Tab in the up position (1 wire).
2. If your old thermostat had both V and VR wires, stop now and contact a
qualified contractor for help.
3. If your old thermostat had separate O and B wires, attach the B wire to the C
terminal. If another wire is attached to the C terminal, stop now and contact
a qualified contractor for help.
4. If your old thermostat had Y1, W1 and W2 wires, stop now and contact a
qualified contractor for help.
5. C does not power the thermostat display or operations; batteries are always required.
6. This model doesn’t support the heat pump fault alert (L/A terminal). If this
is desired, please contact a contractor for replacement model.
AUX
G
C
Y
L/A
O/B
E
3 5
3
4
or X or B
or F
or Y1 or M
or H or B
or V or VR
or W or W1 or W2
or X or X2
or F
21
M39555
6
IMPORTANT: Do NOT
use W for heat pump
applications. Auxiliary heat
must wire to AUX or E.
5 Confirm wiring matches snapshot.
Confirm wiring matches terminals from the photo you took during removal.