Alternate wiring (conventional systems)
If labels do not match terminals, connect wires as shown below (see notes below).
WIRING NOTES:
1. If you must connect both R and Rc wires, set the R Slider Tab to the down
position (2 wires).
2. If your old thermostat had both R and RH wires, set the R Slider Tab to the
down position (2 wires). Then connect the R wire to the Rc terminal, and the
RH wire to the R terminal.
3. If your old thermostat had only 1 C or C1 wire, connect it to the C terminal. If
your old thermostat had 2 C or C1 wires, wrap each separately with electrical
tape and do not connect them.
4. C does not power the thermostat display or operations; batteries are always required.
Wiring
Conventional Systems
AUX
M36687
C
Y
G
C
Y
A
Rc
W
K
W
2
R
L/A
O/B
E
Y
4
2
2
or Y1 or M
or F
or C1 or X or B
or W1 or H
or RH or 4 or V
3
S
S
U
U
2
Heat Pump
WIRING NOTES:
1. Match each labeled wire with same letter on new thermostat.
2. Insert the wires into the matching terminal.
NOTE: If you have difficulty inserting wires, you may have to press down the
terminal push button next to the corresponding terminal. If the labels do not
match the letters on the thermostat, see the diagram above.
AUX
M36266B
Y
G
C
Y
A
Rc
W
K
W
2
R
L/A
O/B
E