8
Alternate wiring (for heat pump systems only)
WIRING NOTES:
1. Keep R Slider Tab in the up position (1 wire).
2. If your old thermostat had both V and VR wires, stop now and contact a
qualified contractor for help.
3. If your old thermostat had separate O and B wires, attach the B wire to the C
terminal. If another wire is attached to the C terminal, stop now and contact
a qualified contractor for help.
4. If the O/B connection is used the thermostat will not support W, Aux/W2 or
E wires.
5. C does not power the thermostat display or operations; batteries are always required.
6. This model does not support the heat pump fault alert (L/A terminal). If this
is desired, please contact a contractor for replacement model.
AUX
G
C
Y
L/A
O/B
E
3 5
3
or X or B
or F
or H or B
or V or VR
or F
21
M39563
6
4