20.1.2 Visual inspection of oil levels
Check oil levels of feed gear (1) before starting work or after
every maintenance and repair. Oil level must reach at least to
the middle or top mark.
20.1.3 Oil change feed gear
NOTICE
Lubricants are toxic and must not be released into the environment. When
changing, use suitable collecting containers with sufficient volume! Follow
the manufacturer's instructions and, if necessary, contact your local
authority for further information on proper disposal.
Supply gear oil (recommended for ISO 12925-1 CKD, DIN51517 Part 3 CLP, US Steel 224, AGMA
9005-E02) with a viscosity of 220.
Feed gear
Make sure that the oil level always reaches the mark of the
sight glass. To change the oil remove the cover on the left
side of the headstock, drain the oil by removing the drain plug
(D). To refill the oil use the refill opening (F). Remount the
cover. Check the oil level regularly.
First oil change (running-in oil) after 100 operating hours,
then change the oil once a year or after 1000 operating hours.
Gear wheels
Lubricate the gears with a heavy, non-spinning grease. Make sure that no grease gets onto belt
pulleys or belts!
Grease nipples and lubricators
Lubricate or fill grease nipples or oilers on the
leadscrew, on the tailstock as well as on the
face and top slides with machine oil weekly.