– 29 –
Error
No.
Text On Screen Error Description Troubleshooting
074
detergent.
The detergent has not been
sensed for the set number
of consecutive cycles.
Ensure detergent is present in bottle and
that cap & tube are properly secured to
bottle. Replace detergent bottle if empty.
Press the ENTER button to prime the
detergent pump. Repeat as required.
075
rinse aid.
The rinse aid has not been
sensed for the set number
of consecutive cycles.
Ensure rinse aid is present in bottle and that
cap & tube are properly secured to bottle.
Replace rinse aid bottle if empty. Press the
ENTER button to prime the rinse aid pump.
Repeat as required.
076
sanitizer.
The sanitizer has not been
sensed for the set number
of consecutive cycles.
Ensure sanitizer is present in bottle and that
cap & tube are properly secured to bottle.
Replace sanitizer bottle if empty. Press the
ENTER button to prime the sanitizer pump.
Repeat as required.
077 Detergent empty. Machine
locked.
Detergent has not been
sensed for three consecu-
tive cycles.. The machine
will be locked out until
detergent is replaced.
Ensure detergent is present in bottle and
that cap & tube are properly secured to
bottle. Replace detergent bottle if empty.
Press the ENTER button to prime the
detergent pump. Repeat as required.
079 Sanitizer empty. Machine
locked.
Sanitizer has not been
sensed for three consecu-
tive cycles. The machine
will be locked out until
detergent is replaced.
Ensure sanitizer is present in bottle and that
cap & tube are properly secured to bottle.
Replace sanitizer bottle if empty. Press the
ENTER button to prime the sanitizer pump.
Repeat as required.
080 Delime required. Run de-
lime cycle.
If delime lockout is enabled,
machine will lock out due
to delime reminder being
ignored 10 times.
Press the ENTER button and run a delime
cycle to reset the delime reminder.
081 Final rinse temperature too
high.
Final rinse temperature is
239°F/115°C or greater.
Press and hold the power button for
5 seconds to clear the error. The machine
will drain and power off. If the error persists,
contact Hobart Service.
082 Final rinse temperature too
low.
Final rinse temperature is
32°F/0°C or lower.
Press and hold the power button for
5 seconds to clear the error. The machine
will drain and power off. If the error persists,
contact Hobart Service.
083 -
perature not reached.
rinse temperature after
three consecutive cycles.
Press the ENTER button to clear the error. If
the error persists, contact Hobart Service.
084 -
perature not reached.
Machine locked. temperature did not reach
temperature after three
consecutive cycles, the
machine will lock out.
Press and hold the power button for
5 seconds to clear the error. The machine
will drain and power off. If the error persists,
contact Hobart Service.