Hobart LXNR-2 handleiding
Handleiding
Je bekijkt pagina 10 van 32

– 10 –
Chemical Sanitizer (Models LXnC & LXGnPR)
Items such as pewter, aluminum and silver will be attacked by sodium hypochlorite (bleach).
Therefore, chemical-sanitizing dishwashers should not be used to wash such items.
On models LXnC & LXGnPR, the chemical sanitizer pump is factory-set for use with 6% sodium hypochlorite
solution.
On LXnC models, place a 1-gallon bottle of 6% or 8.40% sodium hypochlorite solution (bleach) in a suitable
On LXGnPR models, place a sanitizer approved for potable water rinse machines in a suitable location no higher
Never premix a wetting agent with the sanitizing solution. Mixing may cause hazardous
gas to form.
Remove the sanitizer bottle cap and place the white delivery tube in the sanitizer container. Be sure to push the
delivery tube standpipe completely to the bottom of the container. Check to make sure there are no obstructions
or kinks in the delivery tube.
Testing Sanitizer Concentration (Models LXnC & LXGnPR)
completely to the bottom of the chemical container. Place a glass rack, with glasses, in the machine.
On LXnC models, press the WASH button to run a cycle. At the end of the cycle, open the door.
On LXGnPR models, the PuriRinse feature must be deactivated to properly check the sanitizer concentration.
To deactivate PuriRinse, press the MENU button in the upper right corner of the display. Using the Up & Down
arrow buttons, scroll down until Check Sanitizer is highlighted and press the ENTER button. Highlight Yes and
press the ENTER button. Press the WASH button to run a cycle without PuriRinse. At the end of the cycle,
open the door.
Follow the directions precisely that are on the litmus paper vial and test the water on the surface of the bottom
of the glasses. Concentration should be 50 p.p.m. minimum to 100 p.p.m. maximum.
Deliming Solution
All LXnR, LXGnR and LXGnPR models are equipped with an automatic deliming system. At installation, a
properly set the delime intervals.
Remove the deliming agent bottle cap and put the black delivery tube in the container.
Be sure to push the delivery tube standpipe completely to the bottom of the container. Check to make sure there
are no obstructions or kinks in the delivery tube.