Chemical Pump Priming
When a chemical becomes empty, the priming operation automatically starts the next time the machine is
turned on or a wash cycle is started. Note that the initial prime time for all pumps (Detergent, Rinse Aid and
Sanitizer) is 60 seconds. If the chemical is not sensed within 60 seconds, the add chemical indicator will
display. After the chemical is sensed, the indicator turns off and the pump continues to prime for 10 seconds
to allow the chemicals to reach the machine.
If chemicals are not sensed after three consecutive wash cycles, an error will display for the corresponding
chemical. Ensure the corresponding chemical bottle is not empty and that the cap and tube are properly
secured to the chemical bottle. Replace the chemical bottle if empty. Press the ENTER button to prime the
chemical pump.
If the chemical bottles are not empty and the delivery tube standpipes are inserted correctly, then the
To manually prime the chemical pumps, follow the steps below.
1.
2. Press the Menu button located in the upper right corner of display.
3. With Manager Menu highlighted, press the Enter button. The Enter PIN screen will be displayed.
4. The default manager code is 1001. Use the arrow buttons to change the value and then press the Enter
button to select the value and toggle to the next digit until the code is entered.
5. After pressing Enter for the last digit, use the down arrow and scroll until Chemical Menu is outlined.
Press Enter.
6. Scroll down until Prime Chemical Pumps is outlined. Press Enter.
7. Prime Detergent Pump is displayed. Use the arrow keys to select Yes or No to prime the detergent
pump. Press Enter button.
8. Prime Rinse Aid Pump is displayed. Use the arrow keys to select Yes or No to prime the rinse aid pump.
Press Enter button.
9. Priming Sanitizer Pump is displayed. Use the arrow keys to select Yes or No to prime the sanitizer
pump. Press Enter button.
10. Filling Chemical Hoses is displayed and the appropriate chemical pump(s) set to Yes in Steps 7 - 9 will
prime for 20 seconds and the display will revert back to the Chemical Menu.
11. To exit the menu, use the Up and Down Arrows to scroll thru the parameters until Back is outlined and
press the Enter button. Repeat this procedure until the Ready screen is displayed.