Helios MiniVent M1/120 handleiding

48 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 26 van 48
MiniVent M1/100/120
Installation and Operation Instructions
8
4. Mounting flange MF 100 (Accessories)
If there are space restrictions in ceilings, in thin walls and in narrow shafts. Attach MF 100 to the wall or ceiling at a
suitable angle (any number possible). Then fasten the fan to the MF 100 with the provided screws (fig. 10/11). Also
suitable for mounting a pull-cord switch (Accessories).
6.3 Electrical connection
The safety instructions in chapter 1.2 must be observed!
The electrical connection and initial start-up are to be carried out in accordance with the relevant wiring dia
gram and are only to be carried out by a certified electrician.
All relevant standards, safety regulations (e.g. DIN VDE 0100), as well as the technical connection conditions
of energy suppliers are to be adhered to!
A multipole mains section switch/isolator, with a minimum contact opening of 3 mm (VDE 0700 T1
7.12.2 / EN 60335-1) is mandatory!
– Network configuration, voltage and frequency must be consistent with the rating plate information.
6.4 Connection of the supply line / Start-up
A commercially available NYM line must be used, maximum diameter 11 mm
Pre-pierce grommet with round tool or pierce directly with supply line (fig.9, Pos
)
Remove sheath to100 mm. Strip wires to 7 mm (fig.12)
Carefully push cable through the grommet
Place wires in the cable channel and connect according to wiring diagram (page 10)
Check the waterproofing of the connection cable and tight clamping of the strands
If the grommet does not evenly enclose the sheathed cable once the supply line is installed, the grommet must be
additionally sealed, e.g. with Silicone N. Otherwise, the IP protection will expire
The connection cable and the control line must be stored so that no water can get in along the cable in case of
water exposure. The cables must not be placed over sharp edges!
Check designated use of fan
Compare mains voltage to rating plate data
Check fan for solid mounting and professional electrical installation
UK
fig.11
Ceiling
MF 100
fig.10
MF 100 snap-on
Wall
in
s
t
al
l
a
tion
de
pt
h
12
32
52
WARNING
DANGER

Bekijk gratis de handleiding van Helios MiniVent M1/120, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkHelios
ModelMiniVent M1/120
CategorieVentilator
TaalNederlands
Grootte5307 MB