3e. Installation of the mechanical ow switch
Installation and connection of the mechanical flow switch:
Install the flow switch mount.
Unscrew the white protective cover of the mechanical flow switch.
Screw the flow switch onto the 3/4" male thread.
Connect the red and black cables to the electronic circuit board terminals E and F.
p
H
O
R
P
Probe
holder
pH probe
Flow switch
Earthing
anode
Temperature
probe
ORP probe
Liquid
acid
injection
Liquid
chlorine
injection
4. PREREQUISITES FOR STARTING THE CHEMICAL TREATMENT
Preparing the pool water
In preparation for operation of the treatment, the chemical composition of the pool water must be balanced. This equilibrium
must be established BEFORE activating the NG Control Station. Certain adjustments of the chemical equilibrium of the
pool can take several hours. The procedure must therefore be started long before the NG Control Station is turned on.
Chemical water balance
The water must be balanced manually BEFORE the device is started up.
The following table summarizes the concentrations recommended by Hayward. Your water should be checked regularly to maintain
these concentrations and minimize surface corrosion or deterioration.
CHEMISTRY RECOMMENDED CONCENTRATIONS
Free chlorine 1.0 to 3.0 ppm
pH 7.2 to 7.6
Cyanuric acid
(Stabilizer)
20 to 30 ppm max.
(Add stabilizer only if necessary)
0 ppm in indoor pool
Total alkalinity 80 to 120 ppm
Water hardness 200 to 300 ppm
Metals 0 ppm
Langelier index -0.2 to 0.2 (preferably 0)
5. OPERATION
The device is designed to be connected to a protected outlet at all times. The Control Station NG must not be disconnected
unless the pool equipment is undergoing maintenance or the pool is to be closed (wintering).
If the water parameters are within the recommended ranges, the device can be started up.
5b. Commissioning of the device
5a. View and description of the home screen
Conrm the current time and
date using the OK button.
Choose your preferred language
and conrm using the OK
button.
Water temperature in °C
Menu access
Available relays
Max. pH set point (Acid)
Filtration stopped or insufcient ow
Peristaltic pump operation
Maximum injection time reached
Free chlorine sensor ow error
Updated free chlorine measurement
Filtration stopped or insufcient ow
Electrolysis operation
Free chlorine setpoint
Operation
Updated conductivity measurement
Filtration stopped or insufcient ow
Filtration stopped or insufcient ow
Lighting status and programme
Filtration status and programme
Maximum setpoint of ORP
Maximum conductivity setpoint
on/off
3000
7.2
on/off
AL3
FL1
FL1
FL1
FL2
0.00
on/off
1.00
FL1
650
5000
On/Off button
Time