Page 6 on 20 Page 7 on 20Control Station NG Control Station NG
3c. Installation and connection of the electronic circuit boards
Plug the unit into a permanent electrical supply socket.
•
: This circuit must be protected by a residual current device
(RCD) (residual current: 30 mA max.)
and a 16A time-delay circuit-breaker.
Remove the white lid by
unscrewing the 4 screws
using a screwdriver.
1
A
D
E
F
G
H M
N
P
R
V U
S T
Q
O
LKJI
B
C
2
3 4 5 6 7
13128 9 10 11 14
16 18
20
15
17 19
21 22 23
2526
24
3b. Wall-mounted installation
Mount the unit on the wall. The unit must be installed in the plant
room (dry, temperate conditions, ventilated). Take care, acidic vapour
can irreversibly damage your device. Take this into account in the
positioning of the treatment product storage containers.
Unplug the pool lter pump before you begin installing the control
station. The installation must be completed in compliance with the
regulations in effect in the country of installation.
The unit must be installed at a minimum horizontal distance of
3.5 metres (or more, if local legislation requires it) from the pool, and
at less than 1 metre from a protected socket.
The unit must be installed vertically, on a at surface, with the cables
orientated downwards. Don’t mount the unit behind a panel or in an
enclosed space.
All metal pool components can be connected to the same earth in
accordance with local regulations.
(x4)
3d. Cabling the box
6 inputs for equipment cables WiFi / Ethernet module
Drill using an M12 bit
or a tapered bit
Drill using an M16.5 bit
or a tapered bit
Connection of inputs:
Circuit
board
Name Description Terminals Type of input / output
Main ºC Temperature probe (optional) A-B-C Red, yellow, black
Main COVER / AUX Pool shutter position sensor D-F Dry contact
Main
FL1 / FLOW
SWITCH
Mechanical flow switch E-F Non-polarised dry contact
Main SLAVE Terminal for master or slave box G-F Dry contact
Main PH Peristaltic or electromagnetic injection pump H-I Output: Voltage 230 VAC 5A max
Main FILTER PUMP Control of filtration pump J-K Dry contact
Main LIGHT 50W Control and power supply for lighting L-M Output: Voltage 12 VAC 50W max
Main
VARIABLE
SPEED PUMP
Control of variable speed pump N-O-P-Q
Dry contact
V1 - V2 - V3 - Common
Main SCREEN Remote screen (optional) R
Modbus RS465
From top to bottom: red/free/yellow/green/black
Main WIFI WiFi or Ethernet module (optional) S
Modbus RS465
From top to bottom: red/free/yellow/green/black
Main EXTERN Standard communication connector T
Modbus RS465
From top to bottom: red/free/yellow/green/black
Main PH pH Connection chip (optional), with markings and LED on the left U 5 VDC
Main RX ORP Connection chip (optional) with markings and LED on the left V 5 VDC
Extension ION Connector for power supply to copper electrode (not provided)
Extension TANK1 Empty container sensor 1 4-6 Dry contact
Extension TANK2 Empty container sensor 2 3-6 Dry contact
Extension FL2 CL2 Flow switch for free chlorine sensor
5-6-7
for amperometric
5-6
for membrane
Black - brown - blue
Black - red
Extension AUX1 Control and power supply by relay 8-9 Output: Voltage 230 VAC 5A max
Extension AUX2
Preprogrammed relay for peristaltic
or electromagnetic injection pump
10-11 Output: Voltage 230 VAC 5A max
Extension AUX3 Control by relay 12-13 Dry contact
Extension AUX4 Control of heat pump (temperature option) or control by relay 14-15 Dry contact
Extension 4-20mA LOOP1 Reading from free chlorine sensor equipped with membrane 16-17
+: green (+12 VAC) /
-: yellow (4-20mA)
Extension 4-20mA LOOP2 Reading from 4-20 mA probe 18-19 12 VAC 4-20mA
Extension CD Connection of conductivity probe 20
Extension CL2 Connection of amperometric free chlorine sensor 21-22
Extension CL POWER 23-24
Extension CL CL Connection chip (optional) with markings and LED on the left 25 5 VDC
Extension CD CD Connection chip (optional) with markings and LED on the left 26 5 VDC
Power cable ORP probe pH probe