MMA (SMAW) WELDING MODE
INSTALLATION AND GUIDANCE
See power source manual.
PROCESS SETTINGS
Welding processes
Settings Settings Standard Pulsed
Electrode type
Rutile
Basic
Cellulosic
The type of electrode determines the settings in order to optimise its
weldability depending on the type of electrode used.
Anti-Sticking ON-OFF
The anti-stick feature is recommended to safely remove the electrode in
the event of it sticking to the workpiece (the current is cut o󰀨 automati-
cally).
Access to some of the welding parameters depends on the selected display mode: Settings/Display mode: Easy or Expert.
Refer to the HMI manual.
WELDING PROCESSES
• Standard
This standard MMA welding mode is suitable for most welding applications. It enables welding with all types of coated, rutile, basic and cellulosic
electrodes, as well as on all materials: steel, stainless steel and cast iron.
• Pulse
The pulsed MMA welding mode is suitable for upright (PF) applications. The pulsed setting keeps the weld pool cold while promoting material transfer.
Without pulsing, vertical upward welding requires a ‘Christmas tree’ movement, i.e. a di󰀩cult triangular movement. Thanks to Pulsed MMA welding,
it is no longer necessary to perform this movement. Depending on the thickness of your workpiece, a straight upward movement should su󰀩ce.
However, if you want to enlarge your weld pool, a simple sideways movement similar to downheld welding is su󰀩cient.. In this case, you can set the
frequency of your pulsed current on the display screen. This method o󰀨ers greater control of the vertical welding operation.
CHOOSING COATED ELECTRODES
• Rutile electrodes: very easy to use in any position.
• Basic electrodes: it can be used in all positions and is suitable for safety work due to its increased mechanical properties.
• Cellulosic electrodes: a very powerful arc with a high melting speed, its ability to be used in all positions makes it especially suitable for
pipeline work.
CONFIGURING THE SETTINGS
Units
Arc Force
Arc Force is an overcurrent administered to prevent sticking when the electrode or weld bead touches the weld
pool.
Welding current A The welding current is determined by the type of electrode chosen (see electrode packaging).
Duration of Hot Start s
Hot Start is an overcurrent at the ignition stage which prevents the electrode from sticking to the workpiece. The
intensity (% of welding current) and the time (seconds) can be programmed.
Pulse
frequency
Hz PULSE mode’s PULSING frequency.
Percentage Hot Start %
Hot Start is an overcurrent at the ignition stage which prevents the electrode from sticking to the workpiece. The
intensity (% of welding current) and the time (seconds) can be programmed.
Percentage I cold %
Cold weather s
Access to some of the welding parameters depends on the selected display mode: Settings/Display mode: Easy or Expert.
Refer to the HMI manual.
ADJUSTING THE WELDING INTENSITY
The following settings correspond to the applicable current range depending on the type and diameter of the electrode used. These ranges are quite
large as they depend on the usage and the welding position.
electrode Ø (mm) Rutile E6013 (A) Basic E7018 (A)
1.6 30-60 30-55
2.0 50-70 50-80
2.5 60-100 80-110
3.15 80-150 90-140
4.0 100-200 125-210
5 150-290 200-260
6.3 200-385 220-340