GYSFLASH 108.12 / 148.12 / 158.12 CNT FV
EN
38
Original Gysash output conguration
State
Number
Output_5 Output_4 Output_3 Output_2 Output_1
Description
(F) (G) (H) (I) (K)
S00 0 0 0 0 0 Auto-select - inactive
S01 0 0 0 0 1 Auto-select - ready to detect a contact
S02 0 0 0 1 0 Auto-select - contact detected
S03 0 0 0 1 1 Auto-select - Battery type test
S04 0 0 1 0 0 Pb Charge - ready to detect a contact
S05 0 0 1 0 1 Pb Charge - contact detected
S06 0 0 1 1 0 Pb Charge - charging in progress
S07 0 0 1 1 1 Pb Charge - charge complete (maintenance)
S08 0 1 0 0 0 Li Charge - ready to detect a contact
S09 0 1 0 0 1 Li Charge - contact detected
S10 0 1 0 1 0 Li Charge - charging in progress
S11 0 1 0 1 1 Li Charge - charging complete (maintenance)
S12 0 1 1 0 0 EPS - ready to detect a contact
S13 0 1 1 0 1 EPS - contact detected
S14 0 1 1 1 0 EPS - in progress (overload)
S15 0 1 1 1 1 EPS - in progress (no overload)
S16 1 0 0 0 0 Power-up -inactive
S17 1 0 0 0 1 Power-up - in progress
S18 1 0 0 1 0
Output states not used
S19 1 0 0 1 1
S20 1 0 1 0 0
S21 1 0 1 0 1
S22 1 0 1 1 0
S23 1 0 1 1 1
S24 1 1 0 0 0 Device error
S25 1 1 0 0 1 Operating error
S26 1 1 0 1 0
Output states not used
S27 1 1 0 1 1
S28 1 1 1 0 0
S29 1 1 1 0 1
S30 1 1 1 1 0
S31 1 1 1 1 1
USING SEVERAL GYSFLASH UNITS IN PARALLEL
It is possible to connect several Gysash units together in parallel and connect them to the same system you want to power (e.g.
battery, vehicle, etc.) in order to deliver more current.
There are two ways of doing this:
• Method n°1: Without parallelization module
The Gysash can be parallelized without an additional module. However, with this conguration, not all operating modes are com-
patible, and certain precautions need to be taken regarding cabling.
Compatible modes:
CHARGE SUPPLY AUTO-SELECT POWER-UP
Precautions :
The output cables of each Gysash must not be interconnected with each other, except via the system that is being
powered.
Otherwise, the disconnection protection would not work, and voltage could continue to be supplied when the
system is disconnected, while the Gysash units are still connected to each other.