GYSFLASH 108.12 / 148.12 / 158.12 CNT FV
EN
24
GENERAL DESCRIPTION
Your Gysash is a high-power, multifunctional, professional power supply. It features inverter technology designed to provide energy
support for low-voltage industrial systems, such as automotive production lines. It also provides optimal charging performance for
maintaining the most advanced batteries. This device can accommodate output cables of up to 8 m. Changing the output cables
requires recalibration (see page 27). It is considered a xed device, not a mobile one.
As standard, your Gysash is supplied with a conguration consisting of 4 modes:
• Charge Mode: dedicated to recharging lead (sealed, Liquid, AGM...) or lithium (LiFePO4) starter batteries.
Supply mode (eg: EPS): a power supply to meet the power requirements of a system (example: motor
vehicles)
• Auto-Select mode : automatically selects the correct mode depending on what is connected to the Gysash output.
• Power-up mode: reactivates a lithium battery in UVP (Under Voltage Protection) state.
Your GYSFLASH is SMART!
The built-in functionality of your Gysash can be extended by adding specic charging modes and proles via USB communication,
and custom congurations.
Your Gysash also oers the facility to retrieve data from hundreds of charges onto your USB stick, for analysis in a spreadsheet.
Additional modules (such as printers, Ethernet communication, CAN Open, TOR, etc.) can also be attached via the dedicated
module sockets.
«Auto-Detect» function:
The Gysash is equipped with the «Auto-Detect» function, which automatically starts a charge
when a contact is detected at the output of the Gysash. (To activate/deactivate this function, see
page 29)
Auto - Detect
12.
5
v
Charge
«Manual start» function:
The «Manual start» function allows manual start to be authorised or not by pressing the START/
STOP button.
«Auto-Restart» function:
The «Auto-Restart» function automatically resumes the power supply in the event of a power cut.
(To activate/deactivate this function, see page 29).
«Lock» function:
It is possible to lock modes with a «user» password, and also dene the value of this password.
All the modes marked with a padlock have access restricted by a «user» password (to set the lock,
see page 29).
Password manager
Charge
Auto - select
Password 1
- 2 - 3 - 4
Supply
Power - up
Test
START UP
1. Connect the Gysash to the mains socket.
2. Set the switch to «ON».
3. Select the operating mode you require (Auto-Select -> Charge -> EPS -> Power-up).
To access the Conguration Menu, press the button.
MENU NAVIGATION AND MODE SETTINGS
1 Use the arrows to move around the menu or to change the value or condition of a parameter.
2 Press the SELECT button to enter a sub-menu, select a parameter, or conrm a parameter value.
3 Press the back button to return to the previous menu (or sub-menu).