GPP-1323/GPP-1205 User Manual
46
Setting the
Protection
Level
3. Scroll the knob key to move among
OVP/OCP Level fields. Click the knob
key to enter each field, respectively.
Scroll the knob key to adjust value,
along with the arrow keys to change
among digits followed by clicking the
knob key to confirm set value.
Model
OCP
OVP
GPP-1205
0.25 A to
5.5 A
1 V to 22 V
GPP-1323
0.15 A to
3.3 A
1.8 V to
35.2 V
Note
āThe OVP setting range is from 5 % to 110 % of the
rated output voltage.
āThe OCP setting range is from 5 % to 110 % of the
rated output current.
Setting the
Delay Time
4. Scroll the knob key to move between
OCP Delay fields. Click the knob key to
enter each field, respectively. Scroll the
knob key to adjust value, along with the
arrow keys to change among digits
followed by clicking the knob key to
confirm set value.
Setting Range
OCP Delay
0.20 s to 2.50 s