Error code
Description
Troubleshooting
Error 701
Backup box grid-
side relay failure
1. Check if the communication cable between the
inverter and the backup box is properly
connected.
2. If the error message persists, please contact
Growatt support.
Error 703
Backup box on-
grid overload
1. Restart the backup box.
2. If the error message persists, please contact
Growatt support.
Error 705
Overheat inside
the backup box
1. Reduce the load.
2. If the error message persists, please contact
Growatt support.
9493
12.2.2 Battery fault
Error code
Description
Troubleshooting
Battery
Error 404(0)
BM to PM
undervoltage
2. If the fault message still exists, contact the
manufacturer.
1. Power off the machine and check the power
cables, then restart the machine.
Battery
Error 406(0)
BM to PM
transient
overvoltage
1. Power off the machine and check the power
cables, then restart the machine.
2. If the fault message still exists, contact the
manufacturer.
Battery
Error 407(0)
BM to PM open
circuitedBM
1. Power off the machine and check the power
cables, then restart the machine.
2. If the fault message still exists, contact the
manufacturer.
Battery
Error 408(0)
Over-Temp
1. Power off the machine and wait for 30
minutes before you restart the machine.
2. If the fault message still exists, contact the
manufacturer.
Battery
Error 409(2)
PM to INV
transient
overvoltage
1. Restart the machine.
2. If the fault message still exists, contact the
manufacturer.
Battery
Error 411(0)
communication
with INV
Abnormal
2. If the fault message still exists, contact the
manufacturer.
communication cables between PM and INV,
then restart the machine.
1. Power off the machine and check the
Battery
Error 411(1)
Abnormal serial
control chip
with the master
communication
communication cables between PM and PM,
then restart the machine.
2. If the fault message still exists, contact the
manufacturer.
1. Power off the machine and check the
Battery
Error 411(2)
with INV
Abnormal
communication
2. If the fault message still exists, contact the
manufacturer.
communication cables between PM and PM,
then restart the machine.
1. Power off the machine and check the
Battery
Error 411(5)
with BM
communication
Abnormal
communication cables between PM and PM,
then restart the machine.
1. Power off the machine and check the
2. If the fault message still exists, contact the
manufacturer.

Bekijk gratis de handleiding van Growatt MID 10-30KTL3-XH, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkGrowatt
ModelMID 10-30KTL3-XH
CategorieNiet gecategoriseerd
TaalNederlands
Grootte11746 MB