Maintenance
Testing the 3-Phase Connection
➭
Turn the top
rotary selector switch
(S1) at
the test adapter to the Status C position
(system state: vehicle ready for
charging).
➭ Turn the bottom rotary selector switch
(S2) to each switch position*.
With the exclusion of the exceptions specified
in the following table, a protective conductor
resistance R
PE
of less than 2
is permissible.
This is due to the design of the test adapter.
The PE connection between OUT1 and
OUT2 must also be tested (< 2
).
11.2.2 Testing Insulation Resistance
Testing is conducted in the respective switch
positions for Status B, C or E and in the
green ON position for 3-phase testing at
short-circuited L-N or L1-L2-L3-N contacts
(for earthing contact and CEE respectively)
• at mains connections N1 and N2
• at the power supply end of the test
object, ICCB-IN1
• at the output end of the test object, ICCB-
OUT1
in each case against PE.
The usual limit values apply.
11.2.3 Touch Current Measurement
Touch current measurement is conducted at
the screw connections of the IN sockets
(IN2, IN3 and IN4) with the standard limit val-
ues (I
B
<0,5mA).
11.3 Fuse Replacement
The test adapter may only be operated with
fuses in flawless condition. Damaged or
defective fuses must be replaced immedi-
ately.
All fuses for neutral and phase conductors
are accessible from the outside.
Attention!
!
Life endangering due to electric
shock!
The test adapter is operated with
electric power. Therefore there is a
general risk of electric shock which
can be fatal or cause severe injury.
– The test adapter must be voltage-
free both before and during changing
the fuse. Switch the test adapter off
and disconnect it from the mains
power supply.
– The test adapter may not be con-
nected to a measuring circuit before
and during cleaning.
Attention!
!
Only install fuses of a type that con-
forms to the details specified in the
Technical Data, see page 9.
No other fuses may not be used in
the test instrument.
Step
Rotary
switch
Protective Conductor Resis-
tance R PE,
Permissible
1 < 2 W
2 < 2 W
3 < 2 W
4 < 2 W
5 < 2 W
6 < 2 W
7 < 2 W
8 < 2 W
9 < 2 W
10
>30MW
11 >30MW