CAUTION 
6-5 
Presence of fire extinguisher 
If any hot work is to be conducted on the refrigeration equipment or any 
associated parts, appropriate fire extinguishing equipment shall be available 
to hand. 
Have a dry powder or CO2 fire extinguisher adjacent to the charging area. 
6-6 
No ignition sources 
No person carrying out work in relation to a refrigeration system which involves 
exposing any pipe work that contains or has contained flammable refrigerant shall 
use any sources of ignition in such a manner that it may lead to the risk of fire or 
explosion. 
All possible ignition sources, including cigarette smoking, should be kept 
sufficiently far away from the site of installation, repairing, removing and disposal, 
during which flammable refrigerant can possibly be released to the surrounding 
space. 
Prior to work taking place, the area around the equipment is to be surveyed to make 
sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall 
be displayed. 
6-7 
Ventilated area 
Ensure that the area is in the open or that it is adequately ventilated before 
breaking into the system or conducting any hot work. 
A degree of ventilation shall continue during the period that the work is carried out. 
The ventilation should safely disperse any released refrigerant and preferably expel 
it externally into the atmosphere. 
6-8 
Checks to the refrigeration equipment 
Where electrical components are being changed, they shall be fit for the 
purpose and to the correct specification. 
At all times the manufacturer's maintenance and service guidelines shall be 
followed. If in doubt consult the manufacturer's technical department for 
assistance. 
The following checks shall be applied to installations using flammable 
refrigerants: 
–
The charge size is in accordance with the room size within which the 
refrigerant containing parts are installed; 
–
The ventilation machinery and outlets are operating adequately and are not 
obstructed; 
–
If an indirect refrigerating circuit is being used, the secondary circuit shall be 
checked for the presence of refrigerant; 
–
Marking to the equipment continues to be visible and legible. Markings and 
signs that are illegible shall be corrected; 
–
Refrigeration pipe or components are installed in a position where they are 
unlikely to be exposed to any substance which may corrode refrigerant 
containing components, unless the components are constructed of materials 