CAUTION 
which are inherently resistant to being corroded or are suitably protected 
against being so corroded. 
6-9 
Checks to electrical devices 
Repair and maintenance to electrical components shall include initial safety 
checks and component inspection procedures. 
If a fault exists that could compromise safety, then no electrical supply shall be 
connected to the circuit until it is satisfactorily dealt with. 
If the fault cannot be corrected immediately but it is necessary to continue 
operation, an adequate temporary solution shall be used. 
This shall be reported to the owner of the equipment, so all parties are advised. Initial 
safety checks shall include: 
–
That capacitors are discharged: this shall be done in a safe manner to avoid 
possibility of sparking; 
–
That there no live electrical components and wiring are exposed while 
charging, recovering or purging the system; 
–
That there is continuity of earth bonding. 
7. 
Repairs to sealed components 
During repairs to sealed components, all electrical supplies shall be disconnected 
from the equipment being worked upon prior to any removal of sealed covers, etc. 
If it is necessary to have an electrical supply to equipment during servicing, 
then a permanently operating form of leak detection shall be located at the 
most critical point to warn of a potentially hazardous situation. 
Attention  shall  be  paid  to  the  following  to  ensure  that  by  working  on  electrical 
components, the casing is not altered in such a way that the level of protection is 
affected. 
This shall include damage to cables, excessive number of connections, terminals 
not made to original specification, damage to seals, incorrect fitting of glands, etc. 
Ensure that apparatus is mounted securely. 
Ensure that seals or sealing materials have not degraded such that they no longer 
serve the purpose of preventing the ingress of flammable atmospheres. 
Replacement parts shall be in accordance with the manufacturer's specifications. 
NOTE: 
The use of silicon sealant may inhibit the effectiveness of some types of leak 
detection equipment. Intrinsically safe components do not have to be isolated 
prior to working on them. 
8. 
Repair to intrinsically safe components 
Do not apply any permanent inductive or capacitance loads to the circuit without 
ensuring that this will not exceed the permissible voltage and current permitted for 
the equipment in use. 
Intrinsically safe components are the only types that can be worked on while 