Goodwe GW50K-SDT-C30 handleiding
Handleiding
Je bekijkt pagina 69 van 127

09 Maintenance
65
No. Fault Cause Solutions
6
Grid
Overfrequency
The frequency
of the grid
exceeds the
local grid
standard range.
1. If occurs occasionally, it may
be caused a short term grid
abnormality. The inverter will
recover automatically after the
grid is normal.
2. If it occurs frequently, please
check whether the grid voltage is
within the allowed range.
• If the grid voltage exceeds the
allowed range, please contact
local power operator.
• If the grid voltage is within
the allowable range, please
modify the Grid Overfrequency
protection value with the
consent of the local power
operator.
7
Grid
Underfrequency
The frequency
of the grid is
below the local
grid standard
range.
1. If occurs occasionally, it may
be caused a short term grid
abnormality. The inverter will
recover automatically after the
grid is normal.
2. If it occurs frequently, please
check whether the grid voltage is
within the allowed range.
• If the grid voltage exceeds the
allowed range, please contact
local power operator.
• If the grid voltage is within
the allowable range, please
modify the Grid Underfrequen-
cy protection value with the
consent of the local power
operator.