GLP JDC Line 1000 handleiding

72 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 13 van 72
German Light Products®
JDC Line 1000 User Manual 13
Regulated gives priority to light output and only operates fans as necessary. If the
fixture is blacked out, fans run at minimum speed. When light output intensity is
increased, temperature regulation increases fan speed to the level necessary to
keep the fixture at optimum temperature.
If light output is set to maximum intensity but the fans can keep the fixture at
optimum temperature, there will be no regulation of light intensity. If the fixture
begins to exceed optimum temperature and fans are running at maximum speed it
will begin to limit light intensity until optimum temperature can be maintained.
Regulated is the default fan mode setting.
High lets the fixture operate at maximum light output and suits operation in high
ambient temperatures. Fans are set to constant operation at high speed. Light
output intensity is limited smoothly if it becomes necessary in order to keep fixture
temperature at optimum temperature level.
Besides maximizing light output in high ambient temperatures, you can use the High
mode to cool down a fixture quickly or to remove dust from cooling fans.
Medium sets fans to constant operation at medium speed. Light output intensity is
reduced to a level where it will normally remain constant at ambient temperatures
of up to 45° C (113° F). Intensity is smoothly limited further if it becomes necessary in
order to keep fixture temperature at optimum temperature level.
Low sets fans to constant operation at low speed and is optimized for minimum
noise. Light output intensity is reduced to a level where it will normally remain
constant at ambient temperatures of up to 30° C (86° F). Intensity is smoothly limited
further if it becomes necessary in order to keep fixture temperature at optimum
temperature level.
In all fan modes, if fixture temperature reaches a dangerous level, LEDs will be shut
down for a period until the fans have brought the temperature down to a safe level.
PWM frequency
You can change the LED dimming PWM frequency in order to avoid flicker and beat
frequencies in video images. To do this, select a new PWM frequency using either the
Control / Settings DMX channel, the Fixture Settings menu in the fixture’s control panel
or RDM.
The default PWM setting is 3000 Hz. You can set the PWM frequency to 2700 Hz,
3000 Hz, 4800 Hz or 9600 Hz. Note that a higher PWM frequency may affect dimming
performance.
The PWM frequency setting is stored in the fixture and is not affected by cycling power
off and on. However, it will be reset to the default frequency if you apply a Fixture
Settings Load Settings Default command or a Service Advanced Load
Factory Backup command in the control menus.
As a rule, you should set all the fixtures in an installation to the same PWM frequency in
order to ensure the same performance.