Manual Control
This submenu gives different options for resetting the fixture manually. It can be
helpful for service or stand-alone issues.
Reset All: Performs a full fixture reset to initialize all features and effects.
Reset P/T: Resets pan and tilt only to initialize pan and tilt positions.
Reset Head: Resets all the features in the head.
Manual DMX
Gives control of the fixture using the fixture’s own user interface. The menu timeout
function is disabled as long this menu is open.
Manual Control: Manually sets a DMX value for each function.
Reset Manual values: Resets all manual control values to default.
Settings that are made using the manual DMX control menu always take priority
over external DMX commands. If external DMX control is connected and you exit
the Manual DMX submenu, the DMX signal takes command again. If no external
DMX control is connected and you exit the Manual DMX submenu, the fixture
continues to display the manually set DMX scene for as long as no DMX signal is
received or until fixture power is cycled off and on. The manual control values
remain stored in memory until you apply a Reset Manual Values command (holding
for 3 seconds to confirm).
Note: When entering manual control, be prepared for the fixture to start moving.
Service
The Service menu is split into two levels: Service and Service Advanced. The
Advanced submenu is for use by trained technicians only. Read the information
below carefully before entering this level.
The Service menu contains the following items:
Live Diagnostic: Calls up an overview of all main fixture information, signal
quality and settings. This can be helpful while troubleshooting or talking to GLP
Service.
iQ.Service Connect: Wakes up the integrated GLP iQ.Mesh Module for 5
minutes and enables connectivity to the GLP iQ.Service App.
Test All: Runs a test sequence of all LEDs for a quick test of the fixture. Press
BACK to stop the test sequence.
Test Pan/Tilt: Runs a test sequence of tilt movement only. Press BACK to stop
the test sequence.
Test LED: Runs a test sequence of the LED pixel only. Press BACK to stop the
test sequence.
Test Zoom: Runs a test sequence of Zoom functionality only. Press BACK to stop
the test sequence.