Test Fans (Auto): Starts a fan self-test. Tries to detect fan errors, clears any
current errors if successful.
Test Fans (Manual): Tests fans one by one manually.
Test Encoders: Auto test for all encoders.
Advanced Service
The Advanced Service level is for trained technicians only. Read the information
below carefully before entering this level. You must confirm by pressing and
holding ENTER for 3 seconds before you can enter this level.
The Advanced submenu contains the following items:
Service Mode: Disables pan, tilt and all display timeouts to make servicing inside
the fixture head easier. This mode is automatically disabled after a power cycle.
Job Offset: Lets you set +/- offsets on mechanical effects. Custom offsets let you
adjust fixtures in multiple installations (to compensate for the different positions
of fixtures in a rig, for example).
Any custom offsets that you create here will not affect the fixture’s effect
calibration.
All custom offsets created here are deleted if you apply a Load Factory Defaults
command.
Reset Counters: Resets the different resettable fixture counters.
Device counters are not reset by a Load Factory Backup command.
Save Settings: Lets you save the current fixture settings to one of the three user
settings presets. You can load a user settings preset that you have saved with a
Load User Settings command (see Fixture Settings Load User Settings).
The default fixture preset cannot be changed.
This command only saves fixture settings (Fan Mode, Color Mix etc.). It does not
save fixture configuration information such as DMX address and DMX mode.
Load Factory Defaults
Reloads all factory defaults over the entire fixture and brings the fixture into
standard show condition.
You must confirm the function for 3 seconds before the default settings are loaded.
Important! The factory default settings that are reloaded with this command
include all data and network configuration parameters such as DMX start address,
IP configuration etc. You may therefore lose communication with your controller.
The Load Factory Defaults command does not affect device counters and
calibration.
Factory Menu
Important! Do not enter the Factory Menu if you are not a trained service
professional with service documentation or clear instructions from GLP Service.
Read the user and service documentation carefully before entering this menu.