Fan modes
Five cooling fan modes let you give priority to lowest fan noise or most powerful
cooling:
● Regulated mode gives priority to light output and only operates fans as
necessary. If the fixture is blacked out, fans switch off after some seconds. Only
the fans that are necessary operate, and they run at minimum speed. When
light output intensity is increased, temperature regulation increases fan speed
to the level necessary to keep the fixture at optimum temperature.
If light output is set to maximum intensity but the fans can keep the fixture at
optimum temperature, there is no regulation of light intensity. If the fixture
begins to exceed optimum temperature and the fans are running at maximum
speed, light intensity is limited until optimum temperature can be maintained.
● High mode sets the fixture to give maximum light output and suits operation in
high ambient temperatures. Fans are set to constant operation at high speed.
Light output intensity is limited smoothly if it becomes necessary in order to
keep fixture temperature at optimum level.
You can also use High mode to cool down a fixture quickly after a period of
operation or to help remove dust from cooling fans.
● Medium mode sets fans to constant operation at medium speed. Light output
intensity is reduced to a level where it will normally remain constant at ambient
temperatures of up to 45° C (113° F). Intensity is smoothly limited further if it
becomes necessary in order to keep fixture temperature at optimum level.
● Low mode sets fans to constant operation at low speed and is optimized for
minimum noise. Light output intensity is reduced to a level where it will
normally remain constant at ambient temperatures of up to 30° C (86° F).
Intensity is smoothly limited further if it becomes necessary in order to keep
fixture temperature at optimum level.
● Minimum mode operates as follows:
- If the fixture is at blackout, all unnecessary fans are shut down completely and
only fans that are absolutely necessary remain active. These fans operate at
low speed.
- As soon as the fixture emits light, other necessary fans may start but will stay
at minimum speed. Light output is limited.
Note: In all fan modes, if fixture temperature reaches a dangerous level, the LEDs
are shut down for a period until the fans have brought the temperature down to a
safe level.
Sub module mode / Sub fixture mode
The impression X5 IP offers two options for controlling the Main module and Sub
module:
● Normal – In this mode, all Sub module channels are subordinate to the Main
module channel group. This means that the intensity and shutter of the Main
module act as master intensity and master shutter for the whole fixture.