Manual DMX
Gives individual control of the fixture using the fixture user interface. The menu timeout
function is disabled as long this menu is open.
Manual Control: Manually sets a DMX value for each function.
Reset Manual values: Resets all manual control values to default.
External DMX values will always have higher priority than manual control commands.
Disconnect the fixture from the data source when using manual control.
Note: When entering manual control, be prepared for the fixture to start moving.
Service
The Service menu is split into two levels: Service and Service Advanced. The Service
Advanced level is for trained technicians only. Read the information below carefully
before entering this level.
The Service menu contains the following items:
Live Diagnostic: Calls up an overview of all main fixture information, signal quality
and settings. This can be helpful while troubleshooting or talking to GLP Service.
iQ.Service Connect: Wakes up the integrated GLP iQ.Mesh Module for 5 minutes
and enables connectivity to the GLP iQ.Service App.
Test All: Runs a test sequence of all LEDs for a quick test of the fixture. Press BACK to
stop the test sequence.
Test Tilt: Runs a test sequence of tilt movement only. Press BACK to stop the test
sequence.
Test LED: Runs a test sequence of the LED pixel only. Press BACK to stop the test
sequence.
Test Zoom: Runs a test sequence of Zoom functionality only. Press BACK to stop the
test sequence.
Test Fans (Auto): Starts a fan self-test. Tries to detect fan errors, clears any current
errors if successful.
Test Fans (Manual): Tests fans one by one manually.
Test Encoders: Auto test for all encoders.
Advanced Service
The Advanced Service level is for trained technicians only. Read the information below
carefully before entering this level. You must confirm by pressing and holding ENTER for
3 seconds before you can enter this level.
The Advanced Service level contains the following items:
Service Mode: Disables tilt and all display timeouts to make servicing the fixture
head easier. This mode is automatically disabled after a power cycle.