GLP impression X5 IP Bar 1000 handleiding
Handleiding
Je bekijkt pagina 22 van 84

www.glp.de X5 IP Bar 1000
22 impression X5 IP Bar 1000 User Manual
If the fixture is set to Scene (Stand-alone) and if a stand-alone scene has been
stored in its memory using the Capture DMX Values command, it will display its
stand-alone scene at all times when it is powered on but not receiving a DMX
signal. You can therefore use this setting if you want fixtures to automatically start
stand-alone operation when you apply power to them.
● Capture DMX Values takes a snapshot of the DMX values that are currently being
received and stores them in the fixture’s memory as its captured scene. The fixture
will display this scene if it is set to Scene (Stand-alone) (see above) and is not
receiving a DMX signal.
Tilt invert
Increasing the tilt DMX value moves the head from its home position towards the front
of the fixture.
Changing the Tilt invert setting to ON inverts the tilt direction so that increasing the tilt
value turns the head towards the back of the fixture.
Position feedback
Tilt auto-correction (position feedback) is normally enabled (ON). Changing this
setting to OFF will disable the position feedback and auto-correction. If you need to
return tilt to its correct position, you must perform a reset.
Tilt disable
Tilt disable is normally OFF. Changing the Tilt disable setting to "Current disable" de-
activates tilt by disabling the tilt motor current.
Note: When changing from ON back to OFF to re-enable tilt movement, you must
carry out a reset before you can operate tilt normally.
Display Mode
Gives different behavior options for the display in the fixture’s control panel. This can
be helpful in case of errors or during service operations. Three settings are available:
● Auto (default): the display automatically switches off after a few seconds if the
fixture is receiving a valid control signal and has not detected an error. If the fixture
is not receiving a valid control signal, the display will flash. If the fixture has
detected an error, the display remains constantly on and shows the error.
● On: The display stays on constantly. This setting can be useful if you are configuring
or servicing the fixture.
● Off: The display will automatically switch off after a few seconds even if the fixture is
not receiving a valid control signal or if it has detected an error. Pressing any button
turns on the display again.